Journal: :The Journal of bone and joint surgery. American volume 2007
Erik J Novak Marc D Silverstein Kevin J Bozic

BACKGROUND Total knee arthroplasty is one of the most clinically successful and cost-effective interventions in medicine. However, implant malalignment, especially in the coronal plane, is a common cause of early failure following total knee arthroplasty. Computer-assisted surgery has been employed during total knee arthroplasty to improve the precision of component alignment. The purpose of th...

Journal: :Prosthetics and orthotics international 1999
S Blumentritt T Schmalz R Jarasch M Schneider

The influence of sagittal plane prosthetic alignment changes on loads applied to the ispilateral knee was investigated using 5 transtibial amputee subjects. The goal was to determine which prosthetic alignment results in the most energy efficient standing and also minimises stresses on knee structures during standing. The electromyogram, the external mechanical loading of the prosthetic leg and...

Journal: :Journal of orthopaedic surgery 2015
Behnam Sharareh Ran Schwarzkopf

This meta-analysis reviewed 12 studies comparing patient-specific instrumentation (PSI) with standard instrumentation (SI) for total knee arthroplasty in terms of postoperative coronal alignment and operation time. There is no significant difference between PSI and SI in terms of hip-knee-ankle angle (overall coronal alignment or mechanical axis), tibial coronal alignment, and operation time.

Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...

Journal: :the archives of bone and joint surgery 0
abolfazl bagherifard iran university of medical science mahmoud jabalameli iran university of medical science hosein ali hadi arak university of medical science mohammad rahbar iran university of medical science tahmineh mokhtari tehran university of medical science hooman yahyazadeh shafa orthopedic hospital, iran university of medical sciences, tehran, iran

background:  distal femur wedge osteotomies for varus or valgus alignment of the lower extremity could be done in either uniplanar or biplanar fashion.:union: time and stability of the osteotomy site has been considered important in this anatomic region. in this study, clinical and radiographic findings of biplane distal femur osteotomy were reported. methods: clinical, functional, and radiolog...

2010

One of the most common modes of failure for total knee arthroplasty is aeseptic loosening of the components [2]. Aeseptic loosening failure of both the femoral and tibial components has been shown to occur if the alignment of the knee occurs outside of ± 3° from the mechanical alignment in the coronal plane [3]. Proper mechanical alignment of the knee is dependent on the correct proximal varus/...

Journal: :Clinical biomechanics 2013
Takahiro Arai Hiroichi Miaki

BACKGROUND Dynamic alignment of "knee-in & toe-out" is a risk factor for anterior cruciate ligament injury and is possibly influenced by static knee alignment, range of tibial rotation and tibial plateau geometry. METHODS Twenty-eight healthy women were classified into valgus, neutral and varus groups based on static alignment of their knees. A 3-dimensional motion analysis was carried out fo...

2012
Amir M Navali Leila Azhar Shekoufeh Bahari Behrouz Nazari

UNLABELLED BACKGROUND The purpose of this study was to assess the concurrent validity of alternative measures of frontal plane knee alignment, namely the radiographic anatomic axis and two clinical measures in patients complaining of knee malalignment as compared with the mechanical axis on full-length radiograph of lower limbs. METHODS The knee-alignment angle was measured in 100 knees of...

Journal: :Orthopedics 2012
H Gene Dossett George J Swartz Nicolette A Estrada George W LeFevre Bertram G Kwasman

The purpose of this study was to compare 2 alignment methods for total knee arthroplasty (TKA): kinematic alignment with the use of patient-specific guides and mechanical alignment with conventional instruments. A randomized, controlled trial of 41 kinematically aligned and 41 mechanically aligned patients was conducted with the patient, radiographic evaluator, and clinical evaluator blinded to...

Journal: :Acta orthopaedica Belgica 2011
Eerik T Skyttä Ville Haapamäki Mika Koivikko Heini Huhtala Ville Remes

Hip-to-ankle radiographs have been used to evaluate lower limb alignment before and after total knee arthroplasty. However, earlier studies have inappropriately used correlation to assess the reproducibility of the radiographs. We determined the reliability of the hip-to-ankle radiograph using the Bland-Altman analysis. Two consecutive hip-to-ankle radiographs were obtained in 52 patients (52 k...