نتایج جستجو برای: k ion selective electrodes

تعداد نتایج: 782912  

Journal: :Chemical communications 2015
Markus Krengel Philipp Adelhelm Franziska Klein Wolfgang Bensch

Iron vanadium sulfide (FeV2S4) was synthesized via a high temperature solid state reaction and was investigated as a cheap anode material for Na and Li ion batteries. Discharge capacities as high as 723 mA h g(-1) (Na) and 890 mA h g(-1) (Li) were found for half-cell measurements at room temperature. The capacity of the Na-FeV2S4 system remained constant at 529 mA h g(-1) after the 10th cycle w...

Elham Eslami Hashem Sharghi Mojtaba Shamsipur, Nahid Tavakkoli

Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...

Journal: :Chemical communications 2013
Junwu Xiao Xianwei Zeng Wei Chen Fei Xiao Shuai Wang

Self-standing single crystalline NiCo2S4 hollow nanorod arrays are prepared for catalysing the polysulfide redox couple in quantum dot-sensitized solar cells (QDSCs). The QDSCs using NiCo2S4 as a counter electrode (CE) achieved a power conversion efficiency of 4.22%, which exceeds the performance of QDSCs based on a Pt CE by 38.4%.

Journal: :Lab on a chip 2009
Sung-Yong Park Sheraz Kalim Caitlin Callahan Michael A Teitell Eric P Y Chiou

We report on a light-actuated, droplet based microfluidic platform enabling two-dimensional (2D) droplet manipulation on an open chamber with a single-side, featureless photoconductive surface. The droplet actuation mechanism is based on recently demonstrated floating electrode optoelectronic tweezers (FEOET), which enable light-induced dielectrophoretic forces to manipulate aqueous droplets im...

2004

A theory for the interpretation of the operation mechanism of ion-selective membrane electrodes is briefly outlined. The statements are based on the accumulated results concerning the electrochemical and spectrochemical behaviour of ion-selective membranes.

Journal: :Clinical chemistry 1985
J Toffaletti K M Lee

We analyzed 93 sera and 81 whole-blood samples, plus several aqueous materials and one serum-based material as controls, with two analyzers for ionized calcium (Radiometer ICA 1 and AVL 980). On 16 days, comparisons of results for patients' samples were good, with nearly all between-instrument differences (delta Ca2+) of samples being within 0.04 mmol/L. On 12 days, comparisons were mediocre, w...

Journal: :The Journal of Automatic Chemistry 1991
Rui A. S. Lapa José L. F. C. Lima

The construction of a microcomputer-controlled electrode switch for use in potentiometric determinations is described. This can be coupled to most of the analytical equipment usually found in laboratories, to enable a setting up of automatic systems capable of performing sequential determinations with several ion-selective electrodes. The assessment of its analytical usage and behaviour are dis...

Journal: :physical chemistry research 2015
maryam hosseini bahram ghalami-choobar mohammad ali zanjanchi

in this work, the results concerning to the mean activity coefficient measurements for nacl in the (glycerol + water) system using the potentiometric method are reported. the potentiometric measurements were performed on the galvanic cells without liquid junction of the type: ag|agcl|nacl (m), glycerol (wt%), h2o (1 - wt)%|na-ise, in various mixed solvent systems containing 0, 5, 10, 20 and 30 ...

2004
I Inkielewicz W Czarnowski J Krechniak

Two analytical procedures, dry combustion and acid extraction, were compared for the preparation of soft animal tissues and other biological samples for determination of fluoride with an ion selective electrode. Both methods were suitable for determining F in the range of 0.5 to 10.0 μg/g with less than 6% error. The combustion method is less laborious but is more accurate. The extraction metho...

Journal: :Clinical chemistry 1987
E Sykes C Grzych E Epstein F L Kiechle

We found the Easy very easy to run and without te#{233}hnique-dependent steps in the procedure. Operators need not have a high level of skill. Calibration is stable for one month, except for the ion-selective electrodes, which must be calibrated every two days. In conclusion, we found the Easy satisfactory in operational and analytical performance. The analyzer is well suited for use in the eme...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید