نتایج جستجو برای: isodose curves

تعداد نتایج: 93941  

H. Alipour, K. Hadad, R. Faghihi,

Background: Due to the small size of the beamlets in IMRT (intensity modulated radiotherapy), physical penumbra is one of the important dosimetric parameters and small changes in the penumbra have a notable impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating...

A. Taherkhani, M. Mohammadi, M.S. Saboori, V. Changizi,

Background: In Radiation Therapy, the sparing of normal tissues can be performed using either multi-leaf collimators or Cerrobend blocks. The current work focuses on the physical characteristics of Cerrobend blocks including attenuation coefficient, effective penumbra width and isodose curves undulation in penumbral regions. Materials and Methods: All measurements were performed using ...

Journal: :Medical physics 2002
Juan Diego Azcona R Alfredo C Siochi Ignacio Azinovic

The goal of IMRT is to achieve an isodose distribution conformed to the tumor while avoiding the organs at risk. For these tasks several gantry angles are selected, each one containing a series of different leaf configurations for the multileaf collimator (MLC) (segments). Verifying the relative distributions as well as the absolute doses is an important step for quality assurance issues. We ha...

Journal: :iranian journal of radiation research 0
a.a. mowlavi physics department, school of sciences, sabzevar tarbiat moallem university, sabzevar, iran f. cupardo servizio di fisica sanitaria, ospedali riuniti di trieste, trieste, italy m. severgnini servizio di fisica sanitaria, ospedali riuniti di trieste, trieste, italy

background: monte carlo and experimental relative dose determination in a water phantom, due to a high dose rate (hdr) 192ir source is presented for real energy spectrum and monochromatic at 356 kev. materials and methods: the dose distribution has been calculated around the 192ir located in the center of 30 cm ×30 cm ×30 cm water phantom using mcnp4c code by monte carlo method. relative dose v...

2016
Hongqing Zhuang Yi Zheng Junjie Wang Joe Y. Chang Xiaoguang Wang Zhiyong Yuan Ping Wang

In this study, we examined the factors contributing to brain radiation necrosis and its predictors of patients treated with Cyberknife radiosurgery. A total of 94 patients with primary or metastatic brain tumours having been treated with Cyberknife radiotherapy from Sep. 2006 to Oct. 2011 were collected and retrospectively analyzed. Skull based tracking was used to deliver radiation to 104 targ...

2017
Om Prakash Gurjar Radha Kishan Paliwal Surendra Prasad Mishra

The aim is to study the density, isodose depths, and doses at different points in slab-pinewood-slab (SPS) phantom, solid phantom SP34 (made up of polystyrene), and chest level of actual patient for developing heterogeneous chest phantom mimicking thoracic region of human body. A 6 MV photon beam of field size of 10 cm × 10 cm was directed perpendicular to the surface of computed tomography (CT...

2016
Dandan Zheng Qinghui Zhang Xiaoying Liang Xiaofeng Zhu Vivek Verma Shuo Wang Sumin Zhou

In lung stereotactic body radiotherapy (SBRT) cases, the pencil beam (PB) dose calculation algorithm is known to overestimate target dose as compared to the more accurate Monte Carlo (MC) algorithm. We investigated whether changing the normalized prescription isodose line affected the magnitude of MC vs. PB target dose differences. Forty-eight patient plans and twenty virtual-tumor phantom plan...

Journal: :iranian journal of medical physics 0
mahbobeh nazarnejad science and research branch, islamic azad university, tehran, iran

introduction dosimetric accuracy is a major issue in the quality assurance (qa) program for treatment planning systems (tps). an important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. in brachytherapy (bt) of gynecological (gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید