نتایج جستجو برای: ion selective electrodes

تعداد نتایج: 429332  

2004

A theory for the interpretation of the operation mechanism of ion-selective membrane electrodes is briefly outlined. The statements are based on the accumulated results concerning the electrochemical and spectrochemical behaviour of ion-selective membranes.

Journal: :Clinical chemistry 1985
J Toffaletti K M Lee

We analyzed 93 sera and 81 whole-blood samples, plus several aqueous materials and one serum-based material as controls, with two analyzers for ionized calcium (Radiometer ICA 1 and AVL 980). On 16 days, comparisons of results for patients' samples were good, with nearly all between-instrument differences (delta Ca2+) of samples being within 0.04 mmol/L. On 12 days, comparisons were mediocre, w...

Journal: :The Journal of Automatic Chemistry 1991
Rui A. S. Lapa José L. F. C. Lima

The construction of a microcomputer-controlled electrode switch for use in potentiometric determinations is described. This can be coupled to most of the analytical equipment usually found in laboratories, to enable a setting up of automatic systems capable of performing sequential determinations with several ion-selective electrodes. The assessment of its analytical usage and behaviour are dis...

2004
I Inkielewicz W Czarnowski J Krechniak

Two analytical procedures, dry combustion and acid extraction, were compared for the preparation of soft animal tissues and other biological samples for determination of fluoride with an ion selective electrode. Both methods were suitable for determining F in the range of 0.5 to 10.0 μg/g with less than 6% error. The combustion method is less laborious but is more accurate. The extraction metho...

Journal: :Clinical chemistry 1987
E Sykes C Grzych E Epstein F L Kiechle

We found the Easy very easy to run and without te#{233}hnique-dependent steps in the procedure. Operators need not have a high level of skill. Calibration is stable for one month, except for the ion-selective electrodes, which must be calibrated every two days. In conclusion, we found the Easy satisfactory in operational and analytical performance. The analyzer is well suited for use in the eme...

Journal: :Optics express 2008
Nemanya Sedoglavich John C Sharpe Rainer Künnemeyer Sergey Rubanov

Excitation and localization of surface plasmon polariton modes in metal-dielectric structures can be utilized to construct nanophotonic materials and devices with tuneable optical dispersion. We present a selective polariton generator (SPG) device that demonstrates switching of light transmission based on surface plasmon antennae principles. This polarization-sensitive structure selectively gen...

Journal: :Lab on a chip 2013
Kameel Abi-Samra Tae-Hyeong Kim Dong-Kyu Park Nahui Kim Jintae Kim Hanshin Kim Yoon-Kyoung Cho Marc Madou

Expanding upon recent applications of interfacing electricity with centrifugal microfluidic platforms, we introduce electrochemical velocimetry to monitor flow in real-time on rotating fluidic devices. Monitoring flow by electrochemical techniques requires a simple, compact setup of miniaturized electrodes that are embedded within a microfluidic channel and are connected to a peripherally-locat...

Journal: :Angewandte Chemie 2007
Eric Bakker Ernö Pretsch

For most chemists, potentiometry with ion-selective electrodes (ISEs) primarily means pH measurements with a glass electrode. Those interested in clinical analysis might know that ISEs, routinely used for the determination of blood electrolytes, have a market size comparable to that of glass electrodes. It is even less well known that potentiometry went through a silent revolution during the pa...

2017
Chunling Wang Hongyan Yuan Zhijuan Duan Dan Xiao

Increasing use of ion-selective electrodes (ISEs) in the biological and environmental fields has generated demand for high-sensitivity ISEs. However, improving the sensitivities of ISEs remains a challenge because of the limit of the Nernstian slope (59.2/n mV). Here, we present a universal ion detection method using an electronic integrated multi-electrode system (EIMES) that bypasses the Nern...

Journal: :Talanta 1983
P A Siskos E P Diamandis E Gillieron J C Colbert

Simple methods are described for the analysis of sulphate, sulphite and dithionate mixtures by potentiometric titration with lead perchlorate (and use of a lead ion-selective electrode). The error and precision are both about 2-5% for the sulphate concentration range 3 x 10(-3) -6 x 10(-4)M. The sulphur content in fuels derived from refuse was determined by potentiometric titration after bomb-c...