نتایج جستجو برای: iodide ion selective electrode

تعداد نتایج: 461721  

Journal: :journal of physical & theoretical chemistry 2012
m. h. fekri m. darvishpour

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best performance was...

Journal: :journal of physical & theoretical chemistry 2012
r. aminameli m. h. fekri h. shafie m. darvishpour h. khanmohammadi

a pvc membrane fe(iii) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.the electrode exhibits a good potentiometric response for fe(iii) over a wideconcentration range 1.0×10-4 to 1.0×10-1m with a slope 19.4±0.5 mv/decade a and a working phrange of 6.5-9.0. it has a fast response time ≤30s.the best performance was observed with themembrance having the 30....

Journal: :journal of physical & theoretical chemistry 2004
h. aghaie m. giahi1 giahi m. aghaei m. arvand3

we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...

Journal: :journal of physical and theoretical chemistry 0
m. h. fekri - m. darvishpour -

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n&apos;1,n&apos;2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best perfo...

Journal: :journal of physical and theoretical chemistry 0
m. aghaie - m. h. fekri - m. giahi - e. baghdar - s. farhadi -

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaei masood giahi majjid arvand mehran aghaei

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

Journal: :journal of physical & theoretical chemistry 2007
m. aghaie m. h. fekri m. giahi e. baghdar s. farhadi

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :journal of physical & theoretical chemistry 2011
m. kia a. islamnezhad sh. shariati

in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...

Journal: :Annals of clinical and laboratory science 1980
C Baker S E Kahn E W Bermes

The effect of adding known amounts of bromide and iodide to a plasma pool an several methodologies for measuring chloride ion has been studied. Methods evaluated were coulometric, colorimetric, and ion-specific electrode. Three different types of electrodes were evaluated in order to assess any improvements which might have been made in recent years. The older electrode methodology showed an ex...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2006
Wen-Ju Xu Ya-Qin Chai Ruo Yuan Lan Xu Su-Li Liu

In this paper, a new PVC-based liquid-membrane anion-selective electrode based on a copper(II) of N,N'-bis(salicylidene)-1,2-bis(p-aminophenoxy)ethane tetradentate complex (Cu(II)BBAP) is described, which displays a preferential potentiometric response to iodide ion at pH 2.0 and an anti-Hofmeister selectivity sequence: I->SCN->ClO4->NO2->H2PO4->NO3->SO4(2-)>Br->Cl-. The electrode exhibits a ne...

نمودار تعداد نتایج جستجو در هر سال