نتایج جستجو برای: insertion torque

تعداد نتایج: 83716  

2014
Renata de Faria Santos Antonio Carlos de Oliveira Ruellas Daniel Jogaib Fernandes Carlos Nelson Elias

OBJECTIVE This study aimed to measure insertion torque, tip mechanical resistance to fracture and transmucosal neck of mini-implants (MI) (Conexão Sistemas de PróteseT), as well as to analyze surface morphology. METHODS Mechanical tests were carried out to measure the insertion torque of MIs in different cortical thicknesses, and tip mechanical resistance to fracture as well as transmucosal n...

2016
Gorka Santamaría-Arrieta Aritza Brizuela-Velasco Felipe J. Fernández-González David Chávarri-Prado Yelko Chento-Valiente Eneko Solaberrieta Markel Diéguez-Pereira José-Antonio Vega Jaime Yurrebaso-Asúa

BACKGROUND This study evaluated the influence of implant site preparation depth on primary stability measured by insertion torque and resonance frequency analysis (RFA). MATERIAL AND METHODS Thirty-two implant sites were prepared in eight veal rib blocks. Sixteen sites were prepared using the conventional drilling sequence recommended by the manufacturer to a working depth of 10mm. The remain...

قطبی, نسترن, مالمیر, کاظم, محمدی, مصطفی, میر, سید محسن,

Background: Sports injuries of the knee joint are very common. There are both contact injuries and non-contact injuries. Contractile injuries may be due to an impairment of the knee joint position sense or a decrease of the quadriceps muscle strength. Using a Kinesio taping method may decrease this impairment. The aim of the current study was to assess the effect of direction and tension of Kin...

Journal: :Journal of the mechanical behavior of biomedical materials 2017
A Dorogoy D Rittel K Shemtov-Yona R Korabi

The success of dental implantation is connected with the so-called implant primary stability, a synonym for the implant anchoring inside the bone. The primary stability is related to the applied peak torque to the implant during the insertion process. This work simulates the process of insertion of a typical commercial implant into the jaw bone (mandible) using a 3D dynamic non-linear finite-el...

2015
Daniel Jogaib Fernandes Carlos Nelson Elias Antônio Carlos de Oliveira Ruellas

The purpose of this work was to study the influence of screw length and bone thickness on the stability of temporary implants. A total of 96 self-drilling temporary screws with two different lengths were inserted into polyurethane blocks (n = 66), bovine femurs (n = 18) and rabbit tibia (n = 12) with different cortical thicknesses (1 to 8 mm). Screws insertion in polyurethane blocks was assiste...

2013
Jalil Ghanbarzadeh Mahboobeh Rajabzadeh Mohammadreza Nakhaei Hamidreza Rajatihaghi Niloufar Tayarani Najjaran

Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one...

Journal: :European journal of orthodontics 2011
C Z Y Whang D Bister M Sherriff

This study compared peak insertion torque values of six commercially available self-drilling mini-implants [Mini Spider® screw (1.5 × 8 mm), Infinitas® (1.5 × 9 mm), Vector TAS® (1.4 × 8 mm), Dual Top® (1.6 × 8 mm), Tomas Pin® (1.6 × 8 mm), and Ortho-Easy® (1.7 × 6, 8, and 10 mm)]. Twenty implants each were drilled into acrylic rods at a speed of 8 rpm using a motorized torque measurement stand...

2017
Michele Tepedino Francesco Masedu Claudio Chimenti

BACKGROUND The aim of the present study was to evaluate the relationship between insertion torque and stability of miniscrews in terms of resistance against dislocation, then comparing a self-tapping screw with a self-drilling one. METHODS Insertion torque was measured during placement of 30 self-drilling and 31 self-tapping stainless steel miniscrews (Leone SpA, Sesto Fiorentino, Italy) in s...

Journal: :The American journal of sports medicine 2001
J J Costi A J Kelly T C Hearn D K Martin

The goals of this study were to evaluate torsional strength and modes of failure in commercially available bioabsorbable interference screws and to test the effect of screw diameter on torsional strength when screws become jammed during insertion. We tested the Arthrex, BioScrew, Endo-Fix, Phantom, and Sysorb screws, all 20 mm in length. Four major modes of failure were encountered. Analysis of...

2009
Joo-Hyun Kwon Chong-Hyun Han Sun-Jai Kim Jae-Seung Chang

STATEMENT OF PROBLEM Implant drivers are getting popular in clinical dentistry. Unlike to implant systems with external hex connection, implant drivers directly engage the implant/abutment interface. The deformation of the implant/abutment interface can be introduced while placing an implant with its implant driver in clinical situations. PURPOSE This study evaluated the change of rotational ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید