نتایج جستجو برای: indirect water bath heater

تعداد نتایج: 642623  

Journal: :IOSR Journal of Mechanical and Civil Engineering 2017

In this paper, a forced circulation solar water heater system is simulated for different hot water consumption profiles using flat plate collectors as well as evacuated tube collectors. The profiles studied are the actual samples of hot water consumption profiles for different commercial centers and institutions. Dynamic simulation outputs of system thermal performance are used as economic anal...

2011
Yannick Allard Michaël Kummert Michel Bernier Alain Moreau

This study compares the performance of five electrical water heater models in the TRNSYS environment. The main capabilities, modeling assumptions and performance of the models are first assessed using an intermodel comparison. The main criteria for comparison are: domestic hot water supply temperature, power demand (time-dependent profile and overall energy use) and vertical temperature distrib...

2015
Seiichi Yamaguchi Daisuke Kato Kiyoshi Saito Sunao Kawai

A simulation model for the CO2 heat pump water heater was developed and validated in this study. Component models of the gas cooler, evaporator, compressor, and expansion valve were constructed with careful consideration for the heat transfer performances. To validate the simulation model, experiments were carried out using an actual CO2 heat pump water heater (water heating capacity: 22.3 kW; ...

Journal: :Journal of water and health 2008
Thomas W Armstrong Charles N Haas

BACKGROUND The quantities of Legionella vary considerably from natural waters to water in contaminated domestic hot water supplies, whirlpool spas and cooling towers, with the risk for LD rising as the Legionella counts grow. We currently report the results from our Quantitative Microbial Risk Assessment (QMRA) model evaluation. We developed the LD QMRA model to better understand Legionella exp...

Journal: :journal of heat and mass transfer research(jhmtr) 2015
mohammad hossein tavakoli khatereh moharramkhani

influence of a vent hood at the exit of exhaust flue gas and flue baffles in the firetube on the temperature and flow fields of a gas tank water heater, as well as thestructure and amount of heat transferred to the water tank has been studiednumerically using two-dimensional steady state finite element simulation.observations show that without a vent hood, there is a downward gas flow in theflu...

Journal: :Journal of the Federated Institutes of Brewing 1903

2014
Jaesung Park Anthony M. Jacobi

A significant portion of the energy consumed by home appliances that uses hot water is used for heating cold supply water. Such home appliances generally use supply water at a temperature lower than the ambient temperature. Thus, the water is normally heated from below the ambient temperature to its designed maximum temperature by the appliance, often using natural gas or an electrical heater. ...

Journal: :Scientific American 1882

Journal: :Water 2021

This paper discusses domestic problem of waiting hot water for the shower use till it reaches satisfactory temperature, which result a lot wastage in fresh water. The outcome from research survey shows that there is no solution now as all solutions were either expensive or with effective results. Local small inline electric heater equipped fuzzy logic controller proposed this to be installed ju...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید