نتایج جستجو برای: implant stability

تعداد نتایج: 344005  

2015
Parth Satwalekar Sandeep Nalla Ramaswamy Reddy Sheeba Glory Chowdary

The stability of the implant at the time of placement and during the development of the osseointegration process are the two major issues governing the implant survival. Implant stability is a mechanical phenomenon related to local factors such as bone quality, quantity, type of placement technique and type of implant used. The application of a user-friendly, clinically reliable, non-invasive m...

2014
Søren Foghsgaard Per Caye-Thomasen

OBJECTIVE To investigate a new wide bone-anchored hearing implant considering initial stability, stability over time, implant loss, and skin reaction. STUDY DESIGN Consecutive, prospective case series. SETTING Tertiary referral center. PATIENTS Twenty adult patients were enrolled. All operations were 1-stage, single-incision technique with subcutaneous reduction. INTERVENTION(S) Measure...

Journal: :Clinical oral implants research 2004
Mark Bischof Rabah Nedir Serge Szmukler-Moncler Jean-Pierre Bernard Jacky Samson

The purpose of the present study was (1) to measure the primary stability of ITI implants placed in both jaws and determine the factors that affect the implant stability quotient (ISQ) determined by the resonance frequency method and (2) to monitor implant stability during the first 3 months of healing and evaluate any difference between immediately loaded (IL) implants and standard delayed loa...

Journal: :Journal of rehabilitation research and development 2009
Brad M Isaacson Richard E Vance Teri G Rosenbaum Chou Roy D Bloebaum Kent N Bachus Joseph B Webster

Developing noninvasive tools that determine implant attachment strength to bone and monitor implant stability over time will be important to optimize rehabilitation protocols following insertion of osseointegrated implants in patients with limb loss. While resonance frequency has been previously shown to correlate with implant stability in dental implants placed in the mandible and maxilla, thi...

2017
Waldemar Reich Ramona Schweyen Christian Heinzelmann Jeremias Hey Bilal Al-Nawas Alexander Walter Eckert

PURPOSE Short implants often have the disadvantage of reduced primary stability. The present study was conducted to evaluate the feasibility and safety of a new expandable short dental implant system intended to increase primary stability. METHODS As a "proof of concept", a prospective clinical cohort study was designed to investigate intraoperative handling, primary and secondary implant sta...

آریامنش, حافظ, خالصی, میثم, فردمال, جواد, فلاحی, سامان, فیروز, فرناز, موسوی, سحر, حیدری, بیژن ,

Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...

2017
Jong-Cheol Park Yun-Ho Kim Hong-Seok Choi Jong-Shik Oh Sang-Hun Shin Yong-Deok Kim

BACKGROUND The purposes of the present study were to compare implant stabilities of mandibular block bone graft and bovine bone graft and to evaluate influencing factors for implant stability in mandibular block bone (MBB) graft. METHODS This retrospective study investigated 1224 cases and 389 patients treated by one surgeon in the Department of Oral and Maxillofacial Surgery of Pusan Nationa...

Journal: :Clinical implant dentistry and related research 2012
Luca Pagliani Alessandro Motroni Antonio Nappo Lars Sennerby

BACKGROUND Computerized tomographs (CTs) are commonly used for presurgical planning of dental implant placement. It is possible that implant stability can be predicted based on quantitative measurements of bone density at planned implants sites with the use of diagnostic software. PURPOSE The aim was to evaluate if there is a correlation between bone density measurements in specific implant p...

Journal: :journal of periodontology and implant dentistry 0
adel pirjamali neisiani mohsen sarafbidabad

background. improving the implantation conditions in order to reduce the failure is always desirable for researchers. the aim of this study was to compare two different types of dental implant materials from biomechnical viewpoint in order to introduce a novel simulation method to select suitable materials for dental implants. methods. in this research, drilling process was performed in the cor...

Journal: :Journal of periodontal & implant science 2016
Se-Ryong Kang Sung-Chul Bok Soon-Chul Choi Sam-Sun Lee Min-Suk Heo Kyung-Hoe Huh Tae-Il Kim Won-Jin Yi

PURPOSE The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. METHODS We measured the impact response of a dental implant placed into swine bone specimens composed of o...

نمودار تعداد نتایج جستجو در هر سال