نتایج جستجو برای: implant length
تعداد نتایج: 352437 فیلتر نتایج به سال:
PURPOSE This study compared the influence of implant design (cylindrical and conical) in the load transfer on bone surrounding 13mm and 7mm length implants under simulated occlusal loading, using photoelastic analysis. METHOD Dental implants of 4mm diameter were divided into four groups, which varied in length and design: Group 1- standard (13 mm) cylindrical implant; Group 2 - standard conic...
In this paper the variation of normal and shear stresses along a path defined on the bone-dental implant interface is investigated. In particular, the effects of implant diameter, collar length and slope, body length, and the effects of four different types of external threads on the interfacial stress distribution are studied. The geometry of the bone is digitized from a CT scan of a mandibula...
PURPOSE The purpose of this study was to evaluate patient, implant, and treatment characteristics to identify possible prognostic factors for implant failure. MATERIALS AND METHODS Out of a database with different dental implant treatment protocols, a research database of 1 randomly selected implant per patient was created. The database consisted of 487 implants. Of these, 80 were withdrawn, ...
PURPOSE The purpose of this study was to obtain anatomical information for installing four zygomatic implants, by measurements of maxillae and zygomata. MATERIALS AND METHODS Linear and angular measurements were obtained from the maxillae and zygomata of 40 dry skulls. RESULTS Based on mean and standard deviation values, the installation angle of the additional implant in the four zygoma te...
OBJECTIVE To assess efficacy of short (6 mm) implants with a novel macrostructure and thread design placed in a compromised bone situations of edentulous posterior regions of maxilla (3-4 mm of bone height under sinus floor) as compared to results of clinical situations treated with simultaneous maxillary sinus grafting and placement of long (≥10 mm) implants of the same company. STUDY DESIGN...
Objectives: This study was to analyze factors that affect peri-implant bone loss around dental implants placed into alveolar cleft sites. Methods: Thirty-one patients with cleft lip and palate (total 46 implants) who underwent implant treatment following secondary bone graft to the alveolar cleft were included in this study. Evaluation at the peri-implant bone level was measured using standard ...
Today, different implant designs exist in the market; however, there is not a clear understanding of which are the best implant design parameters to achieve mechanical optimal conditions. Therefore, the aim of this project was to investigate if the geometry of a commercial short stem hip prosthesis can be further optimized to reduce stress shielding effects and achieve better short-stemmed impl...
STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measure...
the main goal of this study was to evaluate differences in stress distribution relevant to the number of implants under an anterior bridge when combined with a removable partial denture in the posterior region.four three-dimensional finite element models (3d fem) were designed from a mandible containing an implant-supported bridge extending between canines, and a bilateral distal extension remo...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید