According to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. One important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. Conveying efficiency is associated with pressure, which in...
the pressure drop of refrigerant r-134a flow boiling inside a horizontal tube has been investigated experimentally. the test set-up which was used in this investigation is a well instrumented vapor compression refrigeration system. these instruments are thermocouples, flow meter, pressure gauges and the pressure drop measuring apparatus. this system consisted of three electrically heated evapor...
This paper tends to investigate the performance of a separator cyclone used in cement industries in Iran. This investigation was performed using CFD modeling, which is validated by other valid studies. Separator cyclone performance includes of two important parameters as pressure drop and collection ratio. In this presented study, the pressure drop has been considered to assess the performance ...
according to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. one important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. conveying efficiency is associated with pressure, which in...
In this paper, experimentally derived correlations of heat transfer and pressure drop are used in a Pareto based Multi-Objective Optimization (MOO) approach to find the best possible combinations of heat transfer and pressure drop of TiO2-water nanofluid flow in tubes fitted with multiple twisted tape inserts in different arrangement. In this study there are four independent design variables: t...
The pressure drop of refrigerant R-134a flow boiling inside a horizontal tube has been investigated experimentally. The test set-up which was used in this investigation is a well instrumented vapor compression refrigeration system. These instruments are thermocouples, flow meter, pressure gauges and the pressure drop measuring apparatus. This system consisted of three electrically heated evapor...
outdoor experiments on a once-through single glazed solar air heater with perforated metal absorber plate were conducted to determine the practical effect of absorber plate porosity as well as suction air flow rate on the collector thermal efficiency and its total pressure drop. three aluminum absorber plates were made perforated by drilling circular holes with different diameter/pitch ratios i...
the effect of γ-al2o3 nanoparticles on heat transfer rate, baffle spacing and pressure drop in the shell side of small shell and tube heat exchangers was investigated numerically under turbulent regime. γ-al2o3-water nanofluids and pure water were used in the shell side and the tube side of heat exchangers, respectively. since the properties of γ-al2o3-water nanofluids were variable, they were ...
asymmetric polyethersulfone (pes) microfiltration flat sheet membranes were composed by the phase inversion method (pim) and were used as supports. composite membranes were fabricated by coating silicone rubber as selective layer. effect of different concentrations of pes and pdms and different solvent such as nmp, dmf and dms effects as pes solvents and support thickness and different coagulat...