نتایج جستجو برای: hood performance

تعداد نتایج: 1052094  

Journal: :journal of heat and mass transfer research(jhmtr) 2015
mohammad hossein tavakoli khatereh moharramkhani

influence of a vent hood at the exit of exhaust flue gas and flue baffles in the firetube on the temperature and flow fields of a gas tank water heater, as well as thestructure and amount of heat transferred to the water tank has been studiednumerically using two-dimensional steady state finite element simulation.observations show that without a vent hood, there is a downward gas flow in theflu...

Journal: :Journal of occupational and environmental hygiene 2004
Rong Fung Huang Gene Shin Liu Shin Yi Lin Yu-Kang Chen Shun-Chih Wang Chiung-Yu Peng Wen-Yu Yeh Chun-Wann Chen Cheng-Ping Chang

A wake-controlled exterior hood was developed to overcome the negative influence of cross draft on an exterior hood and avoid the operation inconvenience caused by the enclosure of an airflow capture booth. This new type of local exterior hood used the hood suction flow to stabilize the dynamic vortex shedding that was induced when a crossflow passed over a blockage plate, and therefore formed ...

Journal: :Journal of the Korea Academia-Industrial cooperation Society 2013

Journal: :Antimicrobial agents and chemotherapy 1990
J S Bradley J D Connor L S Compogiannis L L Eiger

Health care workers (HCW) are exposed to ribavirin aerosol during therapy of infants with respiratory syncytial virus infections. To assess the degree of HCW exposure, we analyzed air samples from patient rooms and HCW personal breathing zones during ribavirin aerosol delivery by ventilator (two samples), oxygen hood (two samples), and a new vacuum exhaust hood (four samples). HCW exposure to r...

Journal: :International Journal for Research in Applied Science and Engineering Technology 2021

Journal: :E3S web of conferences 2022

A novel range hood (NRH) consisting of a high-efficiency particulate air (HEPA) filter circulation component and exhaust was designed to improve indoor quality. The HEPA with an airflow rate 72 l/s used remove the matter generated by cooking activities return filtered clean room. reject both other pollutants outdoors. Field measurements were carried out in open kitchen two-floor residential hou...

Journal: :Journal of the Korea Academia-Industrial cooperation Society 2014

Journal: :Applied microbiology 1968
R H Staat J W Beakley

The microbiological control efficiency of two class 100 laminar down-flow hoods was determined by using aerosols of Bacillus subtilis var. niger spores. The first unit challenged utilized a slanted eyelid to partially enclose the front work opening. This hood showed nearly perfect control of ambient organisms in the work area. It also gave a 10(6) or greater drop in the number of organisms pass...

Journal: :Canadian Pharmacists Journal / Revue des Pharmaciens du Canada 2019

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید