نتایج جستجو برای: gravimetric method

تعداد نتایج: 1632378  

Journal: :Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners 2017
Laurent Carrez Lucie Bouchoud Sandrine Fleury-Souverain Christophe Combescure Ludivine Falaschi Farshid Sadeghipour Pascal Bonnabry

Background and objectives Centralized chemotherapy preparation units have established systematic strategies to avoid errors. Our work aimed to evaluate the accuracy of manual preparations associated with different control methods. Method A simulation study in an operational setting used phenylephrine and lidocaine as markers. Each operator prepared syringes that were controlled using a differen...

Journal: :The Biochemical journal 1942
H T Macpherson

In the estimation of very small q-qantities of material there is no question that colorimetric is preferable to gravimetric analysis. The colorimetric method is generally quicker and simpler to carry out-an important factor when numerous analyses are involvedand it is not subject to the manipulative errors incurred in dealing gravimetrically with minute amounts of material. The method, however,...

2016
Sen Guo Jingwei He Weixun Luo Fang Liu

A series of pyridinol-blocked isophorone isocyanates, based on pyridinol including 2-hydroxypyridine, 3-hydroxypyridine, and 4-hydroxypyridine, was synthesized and characterized by ¹H-NMR, 13C-NMR, and FTIR spectra. The deblocking temperature of blocked isocyanates was established by thermo-gravimetric analysis (TGA), differential scanning calorimetry (DSC), and the CO₂ evaluation method. The d...

Journal: :Clinica chimica acta; international journal of clinical chemistry 2009
Nichole L Korpi-Steiner Jennie N Ward Vivek Kumar Joseph P McConnell

BACKGROUND Fecal-fat is typically measured by extracting lipid from homogenized feces with subsequent gravimetric/titrimetric analyses that are time-consuming and involve toxic solvents. Accordingly, an efficient and more safe method to quantitate fecal-fat is needed. The present objective was to adapt CEM SmartTrac technology (i.e. (1)H NMR) to rapidly (< 5 min) quantitate fecal-fat and compar...

2017
Saverio Affatato Filippo Zanini Simone Carmignato

Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive ...

Journal: :Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi) 1989

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید