Journal: :The Journal of hospital infection 2016
O Assadian D J Leaper A Kramer K J Ousey

BACKGROUND Few studies have explored the microbial contamination of glove boxes in clinical settings. The objective of this observational study was to investigate whether a new glove packaging system in which single gloves are dispensed vertically, cuff end first, has lower levels of contamination on the gloves and on the surface around the box aperture compared with conventional glove boxes. ...

2016
Mariko Sugiura Keiji Sugiura

Three cases of occupational dermatitis due to additives to rubber gloves are discussed. These cases were not a result of latex allergy and their dermatitis caused by vulcanization accelerator in rubber gloves. Most people have heard of latex allergy, and some people avoid the use of latex products. However, some rubber-related contact dermatitis of hands is caused by additives such as vulcaniza...

Journal: :Annals of emergency medicine 2004
Vsevolod S Perelman Gregory J Francis Tim Rutledge John Foote Frank Martino George Dranitsaris

STUDY OBJECTIVE Although sterile technique for laceration management continues to be recommended, studies supporting this practice are lacking. Using clean nonsterile gloves rather than individually packaged sterile gloves for uncomplicated wound repair in the emergency department may result in cost and time savings. This study is designed to determine whether the rate of infection after repair...

Journal: :Contact dermatitis 2013
Ann Pontén Nils Hamnerius Magnus Bruze Christer Hansson Christina Persson Cecilia Svedman Kirsten Thörneby Andersson Ola Bergendorff

BACKGROUND An increased frequency of occupational contact hand dermatitis among surgical operating theatre personnel has been noticed. OBJECTIVES To evaluate patients with occupational contact dermatitis caused by their rubber gloves, and to describe a method for analysing the content of the allergens in the gloves. MATERIALS AND METHODS Patch tests were performed with the baseline series, ...

Journal: :International journal of occupational medicine and environmental health 2013
Anna Garus-Pakowska Wojciech Sobala Franciszek Szatko

INTRODUCTION To minimize the risk of cross-infection between the patient and the medical staff, it is necessary to use individual protective measures such as gloves. According to the recommendations of the Centers for Disease Control and Prevention (CDC) and the World Health Organization (WHO), protective gloves should always be used upon contact with blood, mucosa, injured skin or other potent...

2015
Won-Gyu Yoo

[Purpose] The present study examined the effects of wearing rubber gloves on the activities of the forearm and shoulder muscles during two dishwashing stages. [Subjects] This study included 10 young females. [Methods] The participants performed two dishwashing stages (washing and rinsing) with and without rubber gloves. The activities of the wrist flexor and upper trapezius muscles were measure...

Journal: :Contact dermatitis 2012
Denis Sasseville Mimi Thériault

Allergy to natural rubber latex (NRL) gloves in healthcare workers is well recognized, and usually presents as immunological contact urticaria and sometimes anaphylaxis. Latex gloves can also cause allergic contact dermatitis, mostly because of rubber accelerators. As latex sensitivity is well known in healthcare settings, synthetic latex-free gloves are widely used. The most popular latexfree ...

Journal: :Journal of the American Academy of Dermatology 1991
P Rich M L Belozer P Norris F J Storrs

Allergic contact dermatitis developed on the hands and/or face of two patients after exposure to latex examination gloves. Both patients were patch test negative to the usual rubber allergens, but both had a positive patch test reaction to 4,4'-thiobis(6-tert-butyl-m-cresol) (Lowinox 44S36). Patient 2 was also patch test positive to butylhydroxyanisole. The patients were tested with other glove...

Journal: :The Journal of bone and joint surgery. British volume 2004
T Laine P Aarnio

The spread of viral diseases such as HIV has highlighted the importance of protecting medical personnel against contamination from blood. We have assessed the frequency of the perforation of surgical gloves during orthopaedic and trauma surgery and compared the efficiency of single and double gloving. We examined all the gloves used by surgeons for a period of two months. There were 1769 gloves...

2017
Nobuyuki SHIBATA

Anti-vibration gloves have been used in real workplaces to reduce vibration transmitted through hand-held power tools to the hand. Generally materials used for vibration attenuation in gloves are resilient materials composed of certain synthetic and/or composite polymers. The mechanical characteristics of the resilient materials used in anti-vibration gloves are prone to be influenced by enviro...