نتایج جستجو برای: fusion cage
تعداد نتایج: 132510 فیلتر نتایج به سال:
BACKGROUND The transoral atlantoaxial reduction plate (TARP) fixation has been introduced to achieve reduction, decompression, fixation and fusion of C1-C2 through a transoral-only approach. However, it may also be associated with potential disadvantages, including dysphagia and load shielding of the bone graft. To prevent potential disadvantages related to TARP fixation, a novel transoral atla...
OBJECTIVE To retrospectively compare the efficacy of the titanium mesh cage (TMC) and the nano-hydroxyapatite/polyamide66 cage (n-HA/PA66 cage) for 1- or 2-level anterior cervical corpectomy and fusion (ACCF) to treat multilevel cervical spondylotic myelopathy (MCSM). METHODS A total of 117 consecutive patients with MCSM who underwent 1- or 2-level ACCF using a TMC or an n-HA/PA66 cage were s...
Posterior lumbar interbody fusion (PLIF) using cages in conjunction with pedicle screw fixation is considered the gold standard for surgical treatment of degenerative lumbar spine disorders due to its biomechanical stability and high fusion rate. However, research regarding patterns of fusion in the interbody space during the early postoperative period is lacking.Sixty consecutive patients were...
OBJECTIVE Anterior cervical discectomy and fusion (ACDF) is a choice of surgical procedure for cervical degenerative diseases associated with radiculopathy or myelopathy. However, the patients undergoing ACDF still have problems. The purpose of the present study is to evaluate the radiologic results of 3 different methods in single-level ACDF. METHODS We conducted a retrospective collection o...
Introduction: Current cage devices considerably exceed the stiffness of the spinal segment, which may lead to stress-shielding, migration of the cage, and pseudarthrosis. In order to avoid these material related complications, a poly (L-lactic acid) cage device (PLLA cage) has been designed with limited stiffness compared to current cage devices and which will be absorbed on the long term. Biom...
Objectives Cage design and material properties play a crucial role in the long-term results, since interbody fusions using intervertebral cages have become one of the basic procedures in spinal surgery. Our aim is to design a novel Apatite-Wollastonite interbody fusion cage and evaluate its biomechanical behavior in silico in a segmental spinal model. Materials and Methods Mechanical properti...
The authors retrospectively evaluated 30 patients with an anterior cervical interbody fusion for cervical spondylosis or disc herniation. Open box carbon fiber cages were used at 45 levels. The visual analogue scales (VAS), respectively for neck and for arm pain, and the neck disability index (NDI) improved significantly (p < 0.001). Fusion occurred in 87% of the operated levels. Subsidence of ...
This study investigates the biomechanical stability of a large interbody spacer inserted by a lateral approach and compares the biomechanical differences with the more conventional transforaminal interbody fusion (TLIF), with and without supplemental pedicle screw (PS) fixation. Twenty-four L2-L3 functional spinal units (FSUs) were tested with three interbody cage options: (i) 18 mm XLIF cage, ...
BACKGROUND CONTEXT Posterior lumbar interbody fusion (PLIF) was introduced 50 years ago. The Lumbar I/F cage (DePuy Spine, Raynham, MA) was designed to enhance PLIF results. PLIF with the Lumbar I/F cage and posterior Variable Screw Placement System (VSP) has increased the success of fusion to nearly 100% at the four lowest lumbar levels, L2-L3 through L5-S1. Less commonly, PLIF is indicated fo...
BACKGROUND Magnesium (Mg) released from Mg-based implants degradation is believed to be effective in improving osteogenesis, however, studies focusing on Mg-based interbody cages are limited and fusion success was never reported. As excessive Mg accumulation can inhibit new bone formation, this study is designed to explain the possible reasons for the fusion failure of Mg-based cages by analyzi...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید