نتایج جستجو برای: finite element method retrofitting reinforced concrete beam steel

تعداد نتایج: 2161972  

2011
Wei - lun Wang Ju Chen

This study focused on the residual strengths of reinforced concrete beams with heavy deterioration. This work is based on experimental investigation of reinforced concrete beams naturally corroded over 30 years. Visual inspection was firstly conducted and the concrete cracking, spalling of concrete cover, corrosion of rebar were recorded. Material tests on concrete and corroded rebar were also ...

Allah dad Ahmadi Arash Totonchi,

In this paper, a new roofing system is introduced, which is constructued using the precast composite sandwich panels. This roofing sandwich panels system consists of three kinds of precast concrete sandwich panels including capital panels, beam or between columns panels, and slab or middle panels. The panels are composed of three layers; A high strength reinforced concrete top layer. A thick la...

Journal: :Applied sciences 2021

This paper presents a finite element (FE) analysis for predicting the flexural behavior of reinforced concrete (RC) beams strengthened with Fe-based shape memory alloy (Fe-SMA) strips using near surface mounted (NSM) method. Experimental results reported in literature were used to verify proposed FE model. analyses conducted OpenSees, general-purpose structural program. The RC beam specimens mo...

2012
G. W. Ni Y. M. Zhang D. L. Jiang J. N. Chen X. G. Wang

As an economic and safe structure, Bi-steel is widely used in reinforced concrete with less consumption of steel. In this paper, III Bi-steel concrete beam has been analyzed. Through careful observation and theoretical analysis, the new calculating formulae for structural rigidity and crack have been formulated for this Bi-steel concrete beam. And structural rigidity and the crack features have...

2013
George C. Manos Kostas V. Katakalos

The present study investigates the force transfer mechanisms for open hoop fiber reinforced plastic (FRP) strips attached at reinforced concrete (R/C) beams with or without anchorage. These open hoop FRP strips are utilized in R/C beams that are in need of shear capacity upgrade. This type of retrofitting is necessary for R/C structures designed with less stringent seismic loading conditions th...

M. Ahmadi M. Naghipour, M. Nematzadeh

Steel-reinforced concrete (SRC) columns, which are classified as composite columns, became the most widely used in recent years; because of their extensive advantages over the reinforced concrete and the steel columns. In this paper, the ductility index and its influential factors were explored to investigate the behavior of SRC columns. A straightforward approach was then proposed by establish...

2013
N. H. Hamid N. D. Hadi K. D. Ghani

─This paper presents the retrofitting of beam-column joint using CFRP (Carbon Fiber Reinforced Polymer) and steel plate. This specimen was tested until failure up to 1.0% drift. This joint suffered severe damages and diagonal cracks at upper crack at upper column before retrofitted. CFRP were wrapped at corbel, bottom and top of the column. Steel plates with bonding were attached to the two bea...

2006
C. Tort J. F. Hajjar

Accurate assessment of demand and capacity of structures is critical in developing performance-based design methodologies. In this research, new methods are presented towards quantifying demand and capacity of RCFT frames and members. An experimental database was compiled documenting local damage levels of RCFT members. The quantified information collected from the experiments was utilized in c...

In this paper, a new approach for nonlinear numerical modelling of the reinforced concrete shear walls with consideration of bar-concrete interaction and shear deformation is proposed. Bar and concrete stress-strain relations, the bar-concrete interaction, the shear stress-strain relation and, also, their cyclic behavior including the strength degradation and stiffness degradation are adopted a...

Journal: :مهندسی عمران فردوسی 0
سید روح ا.. موسوی محمدرضا اصفهانی مهراله رخشانی مهر

concrete beams reinforced with glass fiber reinforced polymer (gfrp) bars exhibit large deflections and crack widths as compared with steel reinforced concrete beams due to the low modulus of elasticity of gfrp bars. different studies show that aci 318 equation for the effective moment of inertia ie does not predict deflection well for frp reinforced concrete beams. the purpose of this paper is...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید