نتایج جستجو برای: film dosimetry

تعداد نتایج: 98429  

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2013
J Sorriaux A Kacperek S Rossomme J A Lee D Bertrand S Vynckier E Sterpin

PURPOSE To evaluate the uncertainties and characteristics of radiochromic film-based dosimetry system using the EBT3 model Gafchromic(®) film in therapy photon, electron and proton beams. MATERIAL AND METHODS EBT3 films were read using an EPSON Expression 10000XL/PRO scanner. They were irradiated in five beams, an Elekta SL25 6 MV and 18 MV photon beam, an IBA 100 MeV 5 × 5 cm(2) proton beam ...

Ahad Zeinali Kamal Mostafanezhad Leila Mahani Milad Zeinali Kermani

Introduction: The presence of heterogeneities such as air-filled cavities in the head and neck treatment fields region, may result in potential dosimetric disagreement because the losses of charged particle equilibrium. Most of treatments planning systems are not able to predict dose distribution of inhomogeneities region accurately. Therefore, dose calculation algorithms need to...

Journal: :Physics in medicine and biology 2002
Tsang Cheung Martin J Butson Peter K N Yu Peter Metcalfe

Photon beam dosimetry using Kodak extended dose range (EDR2) radiographic film can provide accurate and high spatial resolution information especially for areas such as IMRT dosimetry where a higher dose level (100-400 cGy) is often required to be delivered for verification. For such dosimetry checks, it may sometimes be useful to place the film in a tank filled with water during irradiation. T...

Journal: :Physics in medicine and biology 2000
M J Butsont T Cheung P K Yu D Abbati G E Greenoak

Radiochromic film is tested for its broad-band response to ultraviolet (UV) B (290-320 nm) and A (320 nm400 nm), visible and infrared radiation produced by a solar simulator and examined for dosimetry in ultraviolet radiation. Results show that MD-55-2 radiochromic film in solar and fluorescent light sources responds almost exclusively to broad-band UVA radiation with negligible colouration fro...

Journal: :iranian journal of medical physics 0
reza moghadam-drodkhani m.sc. in medical physics, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran nader riyahi-alam professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran abbas takavar professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran kavous firoznia associate professor, radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran peiman hadad associate professor, radiotherapy dept., imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran behrooz rafiee m.sc., radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran

introduction: the conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. although the polymer gel dosimetry method based on magnetic resonance imaging (mri) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

Journal: :iranian journal of medical physics 0
somayeh nourollahi m.sc.in medical physics, faculty of medicine, tehran university of medical sciences, tehran, iran mahmoud allahverdi associate professor, medical physics dept., faculty of medicine, tehran university of medical sciences, tehran, iran mahbod esfahani m.sc.in medical physics, radiotherapy dept., cancer institute, tehran university of medical sciences, tehran, iran mehdi aghili assistant professor, radiotherapy dept., cancer institute, tehran university of medical sciences, tehran, iran vahid changizi assistant professor, radiology technology dept., faculty of allied medical sciences, tehran university of medical sciences, tehran, iran

introduction: the complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (ptv) result in perturbations in dose distribution. this problem can result in overdosage or underdosage in the match region of the three treatment fields. the purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...

2015
Inhwan J. Yeo Anthony Teran Abiel Ghebremedhin Matt Johnson Baldev Patyal

Radiographic film dosimetry suffers from its energy dependence in proton dosimetry. This study sought to develop a method of measuring proton beams by the film and to evaluate film response to proton beams for the constancy check of depth dose (DD). It also evaluated the film for profile measurements. To achieve this goal, from DDs measured by film and ion chamber (IC), calibration factors (rat...

2010
Jason E. Matney Brent C. Parker Daniel W. Neck Greg Henkelmann Isaac I. Rosen

The purpose of this study was to quantify the performance and assess the utility of two different types of scanners for radiochromic EBT film dosimetry: a commercial flatbed document scanner and a widely used radiographic film scanner. We evaluated the Epson Perfection V700 Photo flatbed scanner and the Vidar VXR Dosimetry Pro Advantage scanner as measurement devices for radiochromic EBT film. ...

2008
Peter L. Roberson Jean M. Moran Ravi Kulasekere

Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of interest encroach on these regions (e.g., head/neck, breast). The current work...

Journal: :Medical physics 2005
Asa Palm Thomas LoSasso

The energy dependence of radiographic film can introduce dosimetric errors when evaluating photon beams. The variation of the film response, which is attributed to the changing photon spectrum with depth and field size, has been the subject of numerous publications in recent years. However, these data show large unexplained differences in the magnitude of this variation among independent studie...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید