The increasing use of modern measuring devices, such as Feeder Terminal Units (FTUs), on power networks can provide multiple types of information for fault location on distribution systems. Using these devices, in this paper, a novel automatic matrix-based algorithm for the identification and isolation of faulted feeder sections on distribution systems is proposed. The algorithm works in two st...
This paper describes the concept and characteristics of smart grid distribution systems, basic difference between conventional and smart grid distribution systems, functional management and reliability evaluation of smart grid distribution systems. In smart grid distribution system, remotely controlled high rated power electronic switches are used in the place of normal disconnecting switches o...
In this paper, bispectral analysis of vibration signals is used to assess health conditions of different rotatingcomponents in an AH-64D helicopter tail rotor drive train. First, cross-bispectral analysis is used to investigate drive-shaft faulted conditions -namely misalignment, imbalance, and a combination of misalignment and imbalance -with respect to a baseline case. The magnitude of the cr...
This paper presents a synchronized phasor measurement-based wide-area backup protection scheme which uses the magnitude of sequence voltages of buses at a system protection centre to identify the faulted bus closest to the fault and faulted line. The technique is tested for various faults including simultaneous faults in various systems with interconnections. The scheme is found to be accurate ...
In early February 2000, primary-to-secondary tube leakage ranging from one to four gallons per day (gpd) was detected in steam generator (SG) No. 24. On February 15, 2000, while the unit was operating at 99% power, SG leakage rapidly increased from 4 gpd to greater than 75 gallons per minute (gpm). The reactor was manually tripped 13 minutes later, and the faulted steam generator was isolated o...
Power system protection in electrical power engineering aims at eliminating a faulted part in an electric network from an otherwise healthy power system. Protection coordination involves a process of best timing any faulted currents so as to reduce the extension of outage areas to a minimum after a fault clearance. In the paper, innovative protection methods and devices widely based on computer...
ABSTRACT Epicyclic gear trains are widely used in various industrial sectors due to their advantages over fixed-axis gears, such as high torque capability, compact size, differential and planetary designs, ease of adjusting gear ratios and even directions of rotation. This research focuses on planetary gearbox whose degree of freedom is one. The geometry and dynamics of the planetary gear train...
Traditional linear spectral analysis techniques of the vibration signals, based on auto-power spectrum, are used as common tools of rotating components diagnoses. Unfortunately, linear spectral analysis techniques are of limited value when various spectral components interact with one another due to nonlinear or parametric process. In such a case, higher order spectral (HOS) techniques are reco...
This paper derives a model of high-voltage overhead power line under fault conditions at low radio frequencies. The derived model is essential for design of communication systems to reliably transfer information over high voltage power lines. In addition, the model can also benefit advanced systems for power-line fault detection and classification exploiting the phenomenon of changed conditions...