2011
S. Xu V. Nagarajan R. Sanishvili

In October 2009, a quad, mini-beam collimator was implemented at GM/CA CAT that allowed users to select between a 5, 10, or 20 micron mini-beam or a 300 micron scatter guard for macromolecular crystallography [1]. Initial alignment of each pinhole to the optical axis of each path through the mini-beam collimator is performed under an optical microscope using an alignment jig. Next, the pre-alig...

Journal: :Medical physics 2005
Xiaochuan Pan Yu Zou Dan Xia

Algorithms have been developed for image reconstruction within a region-of-interest (ROI) from fan-beam data less than that required for reconstructing the entire image. However, these algorithms do not admit truncated data. In this work, we investigate exact ROI-image reconstruction from fan-beam data containing truncations by use of the so-called fan-beam backprojection-filtration (BPF) algor...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 1983
A Brahme J Eenmaa S Lindbäck A Montelius P Wootton

The dose distributional properties of a p(50) Be neutron beam using a continuously variable multi-leaf collimator are presented and compared with a 6 MV photon beam. The differences in physical dose delivery between these two radiation modalities are generally insignificant for radiation therapy, and stringent comparisons of neutron and photon treatments should therefore be possible. The flexib...

Journal: :Physics in medicine and biology 2016
M Vidal L De Marzi H Szymanowski L Guinement C Nauraye E Hierso N Freud R Ferrand P François D Sarrut

Collimators are used as lateral beam shaping devices in proton therapy with passive scattering beam lines. The dose contamination due to collimator scattering can be as high as 10% of the maximum dose and influences calculation of the output factor or monitor units (MU). To date, commercial treatment planning systems generally use a zero-thickness collimator approximation ignoring edge scatteri...

Journal: :Medical physics 2007
Edward E Graves Hu Zhou Raja Chatterjee Paul J Keall Sanjiv Sam Gambhir Christopher H Contag Arthur L Boyer

Treatment of small animals with radiation has in general been limited to planar fields shaped with lead blocks, complicating spatial localization of dose and treatment of deep-seated targets. In order to advance laboratory radiotherapy toward what is accomplished in the clinic, we have constructed a variable aperture collimator for use in shaping the beam of microCT scanner. This unit can image...

Journal: :Medical physics 2006
Qiu Huang Gengsheng L Zeng Jiansheng Wu

An inversion formula was developed by Bukhgeim and Kazantsev for attenuated fan-beam projections [Russian Academy of Science Siberian Branch: The Sobolev Institute of Mathematics (2002)]. The inversion formula was obtained by relating the attenuated fan-beam projections to unattenuated fan-beam projections and by trickily processing the unattenuated fan-beam projections. We show in this paper t...

2013
Hirotsugu Kashiwagi Nobumasa Miyawaki Satoshi Kurashima Susumu Okumura

We are developing an acceptance measurement system to evaluate the matching of the emittance of an injection beam to the acceptance of the AVF cyclotron. The system is composed of a phase-space collimator in the low energy section and beam intensity monitors which are installed just after the phase space collimator and in the high energy section. The phase-space collimator, which consists of tw...

Journal: :Physics in medicine and biology 2015
M Gören Z C Taşkin

Collimator systems used in Intensity Modulated Radiation Therapy can form different geometric aperture shapes depending on their physical capabilities. We compare the efficiency of using regular, rotating and dual multileaf collimator (MLC) systems under different combinations of consecutiveness, interdigitation and rectangular constraints. We also create a virtual freeform collimator, which ca...

Journal: :Medical physics 2005
Qiulin Tang Gengsheng L Zeng Jiansheng Wu Grant T Gullberg

This paper presents analytical fan-beam and cone-beam reconstruction algorithms that compensate for uniform attenuation in single photon emission computed tomography. First, a fan-beam algorithm is developed by obtaining a relationship between the two-dimensional (2D) Fourier transform of parallel-beam projections and fan-beam projections. Using this relationship, 2D Fourier transforms of equiv...