2014
I. W. Eames

Due to the undesirable environmental consequences ofR12, there is a great challenge to find a suitable substitute for Rl2. A new refrigerant blend Rl34a!R218/R600a (88'Yoi9'Yol 3%) called JSCEON 49 has been developed as a long term, zero ozone depletion-potential replacement for Rl2. A computer program was written to calculate the cycle characteristics, such as cooling capacity, coefficient of ...

2003
L. D. Koffman T. Hang

Three evaporators are used to reduce the volume of waste in the waste tank farm at the Savannah River Site (SRS). Evaporators are crucial operation in the SRS waste processing and management system. Using the Aspen Custom Modeler (ACM) software package marketed by Aspen Technology, Inc., the evaporator dynamic flowsheet models have been constructed to simulate the behavior of the evaporator sy...

2014
W. H. Lee Y. J. Kim M. S. Kim K. S. Cho

Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out In this study, HFC-134a is chosen as a working fluid. Test setup is composed of compressor, condenser, expansion valves, two evaporators, and ejector which is installed between two evaporators. The condenser and two evaporators are made as concentric counter-flow type heat ...

2003
John T. Dieckmann Arthur D. Little

The performance of various working fluids for automotive air conditioning was calculated using a computer simulation. The model solves for the steady-state performance of a system that consists of a compressor, condenser, expansion valve, and evaporator, either with or without a liquid line/suction l i e interchanger. Condenser and evaporator performance is calculated based of user-defined valu...

2009
STEPHEN MARKHAM

During the 1999-crushing season, the Malelane Mill installed vibratory screens after the quadruple effect evaporator. The purpose of the screens was to separate out any residual scale originating from the chemical cleaning of the evaporator vessels. This strategy was adopted after attempts to improve the flush out of the evaporator vessels after chemical cleaning proved ineffective in removing ...

2016
Neal Lawrence Stefan Elbel Neal LAWRENCE Stefan ELBEL

Two-phase ejectors are devices capable of improving the performance of refrigeration and air conditioning cycles by means of expansion work recovery. Ejector studies often focus on the design and performance of the two-phase ejector and the effect it can have on the performance of the ejector cycle. However, the ejector is not the only component of the system that can have a significant influen...

2011
J. K. Dabas Sudhir Kumar K. S. Kasana

Experimental investigation was done to find the role of capillary tube length and amount of refrigerant charge on the overall heat transfer coefficient in condenser and evaporator and actual COP of a simple vapour compression refrigeration system. It was concluded that increasing of the refrigerant charge in the system largely enhances the overall heat transfer coefficient in the evaporator by ...

2016
Ze Zhang Rong Xue Shuangtao Chen Shijie Song Yu Hou

For the environmentally aware, natural refrigerant such as CO2 is recommended and pursued by researchers for refrigerators. In this paper, a transcritical CO2 heat pump system was set up to investigate the influence of refrigerant charge on the performance of a small-sized heat pump water heater. The transcritical CO2 heat pump system was composed of a rotary compressor, a tube-in-tube evaporat...

2014
J. W. Linton W. K. Snelson P. F. Hearty F. T. Murphy B. E. Gilbert

The performance of two long term replacements R-407C (HFC-32/125/134a (23%/25%/52%)) and R-410A (HFC-32/125 (50%/50%)) was compared to R-22 in a 10.5 kW (3.0 TR) residential central heat pump. The performance evaluations were carried out in a psychrometric calorimeter test facility located at NRC using the Canadian Standards Association (GSA) I Air-Conditioning and Refrigeration Institute (ARI)...

2014
J. W. Linton W. K. Snelson P. F. Hearty

A series of tests has been completed comparing the system performance of four long term replacements HP62 (44% R~125/ 54% R-143a/ 4% R-134a), AZ-50 (50% R-125/ 50% R-143a), Klea 60 (20% R-32/ 40% R-125/ 40% R-134a), and Klea 61 (1 0% R-32/ 70% R-125/ 20% R-134a) as potential alternatives for the CFC-containing low temperature refrigerant R-502. The tests were carried out under controlled condit...