The main purpose of this research is to analyze the performance of an evaporator for the organic Rankine cycle (ORC) system and discuss the influence of the evaporator on the operating characteristics of diesel engine. A simulation model of fin-and-tube evaporator of the ORC system is established by using Fluent software. Then, the flow and heat transfer characteristics of the exhaust at the ev...
The paper analyzes the various factors that cause failure of refrigerator evaporator. The refrigerator evaporator failure spectrum is constructed through qualitative analysis of the fault tree system after building a corresponding fault tree system. There is an analysis procedure of fault tree system based on computer aided fault tree analysis system (CAFTA).
Microchannel heat exchangers (MCHX) are being increasingly applied in heat pumps because of their compactness, significant charge reduction, lower refrigerant pressure drop and lower air-side fan power consumption compared to traditional round tube-plate fin (RTPF) heat exchangers. Using a microchannel condenser as well as evaporator in a heat pump system also offers significant potential for c...
Liquid recirculation is a method of improving evaporator performance by supplying the evaporator with more liquid than is evaporated. The excess liquid, which is generally provided by means of an externally-driven, mechanical pump, eliminates dryout and increases overall heat transfer coefficient in the evaporator. Liquid recirculation is common in large-scale industrial refrigeration systems, ...
the pressure drop of refrigerant r-134a flow boiling inside a horizontal tube has been investigated experimentally. the test set-up which was used in this investigation is a well instrumented vapor compression refrigeration system. these instruments are thermocouples, flow meter, pressure gauges and the pressure drop measuring apparatus. this system consisted of three electrically heated evapor...
This paper presents the results of the analysis of an ejector refrigeration system operating with Freons as the working substance. Such a system is suitable for operating at subzero evaporator temperatures. The mass of motive refrigerant vaoour per hour per ton and the coefficient of performance are calculated for various assumed operating parameters such as boiler temperature, evaporator temoe...
Title of Document: HIGH-PERFORMANCE TUBULAR EVAPORATOR UTILIZING HIGH ASPECT RATIO MANIFOLD MICROCHANNELS Vibhash Chandra Jha, Doctor of Philosophy, 2012 Directed By: Michael Ohadi, Professor Department of Mechanical Engineering Heat recovery using absorption chillers has not been economical for small scale applications due to high capital requirements and heavy weight/volume as deterring facto...
In the manufacturing of ammonium nitrate, a condensate containing ammonia and ammonium nitrate is obtained. The concentrations of these species are in practically all cases too high for direct discharge into a water recipient. At some plants, some of the dilute ammonium nitrate solution can be spread out on adjacent farmland, as it is a fertilizer, but commonly, nitric acid is added to this str...
Running a refrigeration cycle at saturated liquid conditions at the evaporator inlet has a few interesting advantages in comparison to the conventional 2-phase situation. Opportunities in using novelty heat exchangers, increased cycle efficiency and significantly reduced main compressor sizes occur. Using the two rotor integrated compressor/expander idea developed by Olofsson (1993) in a refrig...