نتایج جستجو برای: echo planar imaging

تعداد نتایج: 526840  

Journal: :Magnetic resonance in medicine 2012
Wei Lin Feng Huang Enrico Simonotto George R Duensing Arne Reykowski

Off-resonance artifacts hinder the wider applicability of echo-planar imaging and non-Cartesian MRI methods such as radial and spiral. In this work, a general and rapid method is proposed for off-resonance artifacts correction based on data convolution in k-space. The acquired k-space is divided into multiple segments based on their acquisition times. Off-resonance-induced artifact within each ...

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2008
Isao Muro Akari Kaneko Masatoshi Honda Tomohiko Horie

Magnetic field inhomogeneity causes artifacts in MRI. For example, in single-shot echo-planar imaging (EPI), they often appear as severe geometric distortions along the phase-encoding direction. Sensitivity encoding (SENSE) is useful in reducing the distortion in EPI since it only acquires partial k-space data using multiple receiver channels. In SENSE, a reference scan usually needs to be perf...

Journal: :AJNR. American journal of neuroradiology 2001
S Chen F Ikawa K Kurisu K Arita J Takaba Y Kanou

BACKGROUND AND PURPOSE Quantification of MR can provide objective, accurate criteria for evaluation of a given MR sequence. We quantitatively compared conventional MR sequences with fast fluid-attenuated inversion recovery (fast-FLAIR) and echo-planar diffusion-weighted (DW) MR imaging in the examination of intracranial epidermoid tumors. METHODS Eight patients with surgically confirmed intra...

Journal: :Magnetic resonance in medicine 1999
S B Reeder E Atalar A Z Faranesh E R McVeigh

Interleaved echo-planar imaging (EPI) is an ultrafast imaging technique important for applications that require high time resolution or short total acquisition times. Unfortunately, EPI is prone to significant ghosting artifacts, resulting primarily from system time delays that cause data matrix misregistration. In this work, it is shown mathematically and experimentally that system time delays...

Journal: :Magnetic Resonance in Medicine 2001

Journal: :Physical review letters 2004
Moritz Hiller Tsampikos Kottos Doron Cohen Theo Geisel

We study the possibility to undo the quantum mechanical evolution in a time reversal experiment. The naive expectation, as reflected in the common terminology ("Loschmidt echo"), is that maximum compensation results if the reversed dynamics extends to the same time as the forward evolution. We challenge this belief and demonstrate that the time t(r) for maximum return probability is in general ...

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2009
Natalia Ares Diego A Wisniacki

Loschmidt echo (LE) is a measure of reversibility and sensitivity to perturbations of quantum evolutions. For weak perturbations its decay rate is given by the width of the local density of states (LDOS). When the perturbation is strong enough, it has been shown in chaotic systems that its decay is dictated by the classical Lyapunov exponent. However, several recent studies have shown an unexpe...

Journal: :Interface focus 2011
Chi Hyung Seo Yan Shi Sheng-Wen Huang Kang Kim Matthew O'Donnell

Thermal strain imaging (TSI) or temporal strain imaging is an ultrasound application that exploits the temperature dependence of sound speed to create thermal (temporal) strain images. This article provides an overview of the field of TSI for biomedical applications that have appeared in the literature over the past several years. Basic theory in thermal strain is introduced. Two major energy s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید