نتایج جستجو برای: dosimetry calculation

تعداد نتایج: 109521  

Ali Soleymani Meigooni Reza Faghihi, Sedigheh Sina

Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...

Journal: :iranian journal of radiation research 0
a.a. mowlavi department of physics, tarbiat moallem university of sabzevar, p.o. box 397, sabzevar, iran a. binesh department of physics, payam nour university of fariman, fariman, iran h. moslehitabar department of physics, payam nour university of mashhad, mashhad, iran

background: palladium-103 (103pd) is a brachytherapy source for cancer treatment. the monte carlo codes are usually applied for dose distribution and effect of shieldings. monte carlo calculation of dose distribution in water phantom due to a med3633 103pd source is presented in this work. materials and methods: the dose distribution around the 103pd model med3633 located in the center of 30×30...

Journal: :Medical physics 2007
Sou-Tung Chiu-Tsao Dennis R Schaart Christopher G Soares Ravinder Nath

Since the publication of AAPM Task Group 60 report in 1999, a considerable amount of dosimetry data for the three coronary brachytherapy systems in use in the United States has been reported. A subgroup, Task Group 149, of the AAPM working group on Special Brachytherapy Modalities (Bruce Thomadsen, Chair) was charged to develop recommendations for dose calculation formalisms and the related con...

Journal: :iranian journal of radiation research 0
f. babapour mofrad faculty of engineering, science and research branch, islamic azad university, tehran, iran r. aghaeizadeh zoroofi control and intelligent processing center of excellence, school of electrical and computer engineering, college of engineering, university of tehran, tehran, iran a. abbaspour tehrani fard electrical and electronic engineering school, sharif university of technology, tehran, iran sh. akhlaghpoor department of interventional radiology, sina hospital, tehran university of medical sciences, tehran, iran y.w. chen college of information and science, ristumeikan university, shiga, japan y. sato division of image analysis, graduate school of medicine, osaka university, osaka, japan

background: in nuclear medicine application often it is required to use computational methods for evaluation of organ absorbed dose. monte carlo simulation and phantoms have been used in many works before. the shape, size and volume in organs are varied, and this variation will produce error in dose calculation if no correction is applied. materials and methods: a computational framework for co...

Journal: :iranian journal of medical physics 0
ali aghaebrahimian department of physics, isfahan university of technology, isfahan, iran mohammad hassan alamatsaz department of physics, isfahan university of technology, isfahan, iran

introduction the gamma knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. dose calculations required in the system are performed by gammaplan code; in this code, brain tissue is considered uniform. in the present study, we evaluated the effect of gamma knife system on the obtained dose through simulating a real h...

2013
Masao Tanooka Hiroshi Doi Hideharu Miura Hiroyuki Inoue Yasue Niwa Yasuhiro Takada Masayuki Fujiwara Toshiyuki Sakai Kiyoshi Sakamoto Norihiko Kamikonya Shozo Hirota

We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic...

Journal: :Medical physics 2012
Sou-Tung Chiu-Tsao Melvin A Astrahan Paul T Finger David S Followill Ali S Meigooni Christopher S Melhus Firas Mourtada Mary E Napolitano Ravinder Nath Mark J Rivard D W O Rogers Rowan M Thomson

Dosimetry of eye plaques for ocular tumors presents unique challenges in brachytherapy. The challenges in accurate dosimetry are in part related to the steep dose gradient in the tumor and critical structures that are within millimeters of radioactive sources. In most clinical applications, calculations of dose distributions around eye plaques assume a homogenous water medium and full scatter c...

Journal: :iranian red crescent medical journal 0
sedigheh sina radiation research center, shiraz university, shiraz, ir iran reza faghihi radiation research center, shiraz university, shiraz, ir iran; department of nuclear engineering, shiraz university, shiraz, ir iran; radiation research center, shiraz university, shiraz, ir iran. tel: +98-7116473474, fax: +98-7116473474 ali soleimani meigooni department of nuclear engineering, shiraz university, shiraz, ir iran; comprehensive cancer center of nevada, las vegas, nevada, usa zahra siavashpour department of radiation medicine, shahid beheshti university, tehran, ir iran mohammad amin mosleh-shirazi center for research in medical physics and biomedical engineering, shiraz university of medical sciences, shiraz, ir iran; department of radiotherapy and oncology, shiraz university of medical sciences, shiraz, ir iran

conclusions according to the results, the old dosimetry formalisms, overestimate the dose especially towards the applicator’s tip. while the tg-43u1 based software perform the calculations more accurately. results for a typical arrangement of 10 active pellets in the applicator, the percentage difference between doses obtained by the new algorithm at 1cm distance from the tip of the applicator ...

2016
Ryosuke Kohno Hidenori Yamaguchi Kana Motegi Kenji Hotta Shie Nishioka Tetsuo Akimoto

The radiation positioning system (RADPOS) combines an electromagnetic positioning sensor with metal oxide semiconductor field-effect transistor (MOSFET) dosimetry, enabling simultaneous online measurement of dose and spatial position. Evaluation points can be determined with the RADPOS. The accuracy of in-vivo proton dosimetry was evaluated using the RADPOS and an anthropomorphic head and neck ...

Journal: :Medical physics 2004
Mark J Rivard Bert M Coursey Larry A DeWerd William F Hanson M Saiful Huq Geoffrey S Ibbott Michael G Mitch Ravinder Nath Jeffrey F Williamson

Since publication of the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report in 1995 (TG-43), both the utilization of permanent source implantation and the number of low-energy interstitial brachytherapy source models commercially available have dramatically increased. In addition, the National Institute of Standards and Technology has introduced a new primary standar...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید