نتایج جستجو برای: dosimetric parameters

تعداد نتایج: 583178  

2012
E. Aguirre J. Arpón L. Azpilicueta S. de Miguel V. Ramos F. Falcone

In this work, the influence of human body within the estimation of dosimetric values is analyzed. A simplified human body model, including the dispersive nature of material parameters of internal organs, skin, muscle, bones and other elements has been implemented. Such a model has been included within an indoor scenario in which an in-house 3D ray launching code has been applied to estimate rec...

2007
Sharifeh A. Dini Shahid B. Awan Kai Dou Ali S. Meigooni

Recently, to eliminate problems associated with seed type sources, RadioMed Corporation (Tyngsboro, MA) introduced RadioCoil 103Pd sources for interstitial prostate implants. The RadioCoil sources are available in integral lengths ranging from 1.0 cm to 6.0 cm. In this project, dosimetric characteristics of these sources were determined following the TG-43U1 recommendations, with consideration ...

2011
Antonio Otal Juan Manuel Martínez-Fernández Domingo Granero

PURPOSE The clinical use of brachytherapy sources requires the existence of dosimetric data with enough of quality for the proper application of treatments in clinical practice. It has been found that the published data for the low dose rate CSM11 Cs-137 source lacks of smoothness in some regions because the data are too noisy. The purpose of this study was to calculate the dosimetric data for ...

2013
Stephen D. Davis William Parker Michael D.C. Evans

Remote afterloading devices used for high-dose-rate (HDR) brachytherapy may be supplied with different sources, and these sources typically have differing initial source strengths. In addition, the proposed frequency for source changes may also vary, depending upon the source type. Dosimetric parameters unique to each source are often used to compare source types. However, when considering the ...

Journal: :Head & neck 2013
Bena Cartmill Petrea Cornwell Elizabeth Ward Wendy Davidson Rebecca Nund Catherine Bettington Reza Masoud Rahbari Michael Poulsen Sandro Porceddu

BACKGROUND Research has reported relationships between 3-dimensional (3D) radiation dose to head and neck structures and consequential swallowing/nutritional outcomes. However, this evidence is preliminary. The current study aimed to identify which reported dose constraints identified functional impairment at 6 months posttreatment. METHODS Dose constraints with reported relationships to swal...

2017
Primož Peterlin Karmen Stanič Ignasi Méndez Andrej Strojnik

BACKGROUND Lung cancer patients are often in poor physical condition, and a shorter treatment time would reduce their discomfort. Dynamic conformal arc therapy (DCAT) offers a shorter treatment time than conventional 3D conformal radiotherapy (3D CRT) and is usually available even in departments without inverse planning possibilities. We examined its suitability as a treatment modality for lung...

Journal: :Medical physics 2016
Antonella Fogliata Jens Fleckenstein Frank Schneider Marc Pachoud Sarah Ghandour Harald Krauss Giacomo Reggiori Antonella Stravato Frank Lohr Marta Scorsetti Luca Cozzi

PURPOSE Flattening filter free (FFF) beams generated by medical linear accelerators are today clinically used for stereotactical and non-stereotactical radiotherapy treatments. Such beams differ from the standard flattened beams (FF) in the high dose rate and the profile shape peaked on the beam central axis. Definition of new parameters as unflatness and slope for FFF beams has been proposed b...

2018
Yasuhiro Hirano Masakatsu Onozawa Hidehiro Hojo Atsushi Motegi Sadatomo Zenda Kenji Hotta Shunsuke Moriya Hidenobu Tachibana Naoki Nakamura Takashi Kojima Tetsuo Akimoto

BACKGROUND The purpose of this study was to perform a dosimetric comparison between proton beam therapy (PBT) and photon radiation therapy in patients with locally advanced esophageal squamous cell carcinoma (ESCC) who were treated with PBT in our institution. In addition, we evaluated the correlation between toxicities and dosimetric parameters, especially the doses to normal lung or heart tis...

2008
A. A. Mowlavi F. Cupardo M. Severgnini

Theoretical and experimental studies have been applied for dosimetric parameters determination of the brachytherapy sources (1-3). Usually, Monte Carlo method has been used to define such quantities as the anisotropy dose function, the radial dose function, and the dose calculation close to the source in brachytherapy (4-6). Ir source is used widely in brachytherapy to treat localized tumors ne...

Journal: :Medical physics 2007
D Granero J Pérez-Calatayud F Ballester

The purpose of this study is to obtain the dosimetric parameters of a new Co-60 source used in high dose rate brachytherapy and manufactured by BEBIG (Eckert & Ziegler BEBIG GmbH, Germany). The Monte Carlo method has been used to obtain the dose rate distribution in the updated TG-43U1 formalism of the American Association of Physicists in Medicine. In addition, to aid the quality control proce...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید