نتایج جستجو برای: dose calculation inhomogeneity phantom tigrt

تعداد نتایج: 427787  

2017
Isaac C. F. Chang Jeff Chen Slav Yartsev

Helical tomotherapy with its advanced method of intensity-modulated radiation therapy delivery has been used clinically for over 20 years. The standard delivery quality assurance procedure to measure the accuracy of delivered radiation dose from each treatment plan to a phantom is time-consuming. RadCalc®, a radiotherapy dose verification software, has released specifically for beta testing a m...

Journal: :iranian journal of nuclear medicine 2003
kamal haddad mehrosadat alavi yeganeh gorji

determination of the total body absorbed dose consists of two parts: beta radiation absorbed dose and gamma radiation absorbed dose. the first part is generally determined by clinical data, while the second part has a parameter called absorbed ratio and is determined by computational methods. the monte-carlo computational methods have been shown to be the most suitable in determination of the a...

A. Abbaspour Tehrani Fard, F. Babapour Mofrad, R. Aghaeizadeh Zoroofi, Sh. Akhlaghpoor, Y. Sato, Y.W. Chen,

Background: In nuclear medicine application often it is required to use computational methods for evaluation of organ absorbed dose. Monte Carlo simulation and phantoms have been used in many works before. The shape, size and volume in organs are varied, and this variation will produce error in dose calculation if no correction is applied. Materials and Methods: A computational framewo...

M. Ansari, M.A. Behrooz, M.J. Tahmasebi Birgani,

 Abstract Background: Adjacent treatment fields are commonly used in external beam radiation therapy, such as mantle and inverted-Y fields for the treatment of Hodgkin’s disease and craniospinal fields used in the treatment of medulloblastoma and head and neck tumors when the lateral neck fields are placed adjacent to the anterior supraclavicular field. In each of these situations, there is a p...

Danial Seifi Makrani Tayyeb Pourfallah

Introduction: Radiotherapy is an effective modality to treat esophageal carcinoma. Due to various inhomogenous tissues with a variety of physical and radiological properties which can cause uncertainty in accurate dose calculations in radiation therapy, accuracy of TPS is very important. The aim of this study was to quantify dose calculation accuracy of CoreplanTM TPS in an inh...

2013
Masao Tanooka Hiroshi Doi Hideharu Miura Hiroyuki Inoue Yasue Niwa Yasuhiro Takada Masayuki Fujiwara Toshiyuki Sakai Kiyoshi Sakamoto Norihiko Kamikonya Shozo Hirota

We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic...

2014
Tae Seong Baek Eun Ji Chung Jaeman Son Myonggeun Yoon

PURPOSE The aim of this study is to evaluate the ability of transit dosimetry using commercial treatment planning system (TPS) and an electronic portal imaging device (EPID) with simple calibration method to verify the beam delivery based on detection of large errors in treatment room. METHODS AND MATERIALS Twenty four fields of intensity modulated radiotherapy (IMRT) plans were selected from...

B.M. Park, B.O. Choi, B.Y. Choe, J.B. Chung, J.W. Lee, J.Y. Jung, T.S. Suh, Y.J. Shin, Y.K. Bae, Y.L. Kim,

Background: Dose calculation algorithms play a very important role in predicting the explicit dose distribution. We evaluated the percent depth dose (PDD), lateral depth dose profile, and surface dose volume histogram in inhomogeneous media using calculation algorithms and inhomogeneity correction methods. Materials and Methods: The homogeneous and inhomogeneous virtual slab phantoms used in th...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2009
Tohru Shiga Yuichi Morimoto Naoki Kubo Norio Katoh Chietsugu Katoh Wataru Takeuchi Reiko Usui Kenji Hirata Shinichi Kojima Kikuo Umegaki Hiroki Shirato Nagara Tamaki

UNLABELLED An autoradiography method revealed intratumoral inhomogeneity in various solid tumors. It is becoming increasingly important to estimate intratumoral inhomogeneity. However, with low spatial resolution and high scatter noise, it is difficult to detect intratumoral inhomogeneity in clinical settings. We developed a new PET system with CdTe semiconductor detectors to provide images wit...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید