نتایج جستجو برای: differential conductometric transducer
تعداد نتایج: 304630 فیلتر نتایج به سال:
Since the first report of graphene, thin two-dimensional (2D) nanomaterials with atomic or molecular thicknesses have attracted great research interest for gas sensing applications. This was due to the distinctive physical, chemical, and electronic properties related to their ultrathin thickness, which positively affect the gas sensing performances. This feature article discusses the latest dev...
A highly sensitive, conductometric and label-free biosensor for the detection of immunoglobulin E (IgE) is developed based on the immobilzation of the IgE aptamer onto a single polyaniline nanowire electrochemically synthesized in a facile and controllable way.
4Nitroquinoline-1-oxide (4-NQO) is a carcinogenic compound. In this paper the change transfer interaction between acceptor 4-NQO and Genetic Bases like Adenine, cytosine, Uracil has been studied with the help of Conductometric Studies.
This status report overviews activities of the German gas sensor research community. It highlights recent progress in the field of potentiometric, amperometric, conductometric, impedimetric, and field effect-based gas sensors. It is shown that besides step-by-step improvements of conventional principles, e.g. by the application of novel materials, novel principles turned out to enable new marke...
Many important issues in transducer arrays design, such as crosstalk, cannot be accurately studied using analytic method due to the complexity of the partial differential equations involved. Finite element method (FEM) is the only appropriate way to gain more detailed information. In this paper, a 2D finite element model is constructed to modeling the structural and acoustic behaviour of transd...
A simple flow injection (FI) conductometric system with gas diffusion separation was developed for the determination of Kjeldahl nitrogen (or proteins) in milk and chicken meat. The sample was digested according to the Kjeldahl standard method and the digest was diluted and directly injected into the donor stream consisting of 4M NaOH. In alkaline medium, ammonium was converted to ammonia, whic...
quantitative determination of br?nsted acid sites in acidic mordenite samples with varying proton concentrations has been studied using aqueous conductometric titration method. conductometric titration of the ammonium form of mordenite with sodium hydroxide is feasible and the results indicate potential number of br?nsted acid sites. however, br?nsted acid sites concentration in acidic mordenit...
Quantitative determination of Br?nsted acid sites in acidic mordenite samples with varying proton concentrations has been studied using aqueous conductometric titration method. Conductometric titration of the ammonium form of mordenite with sodium hydroxide is feasible and the results indicate potential number of Br?nsted acid sites. However, Br?nsted acid sites concentration in acidic mordenit...
conclusions our results indicate that changes in muscle thickness and echo intensity are induced by different inward pressures of the transducer during us. when using a technique that involves a handheld transducer, the examiner should attempt to maintain consistent inward pressure of the transducer during us, to quantify the minimal change of the rf mass and composition. results muscle thickne...
The application of silicalite for improvement of working characteristics of conductometric enzyme biosensors for determination of sucrose was studied in this research. Biosensors based on different types of silicalite-modified electrodes were studied and compared according to their analytical characteristics. Polyethylenimine/glutaraldehyde/silicalite-modified biosensors showed higher sensitivi...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید