نتایج جستجو برای: bromide selective electrode

تعداد نتایج: 276375  

Journal: :journal of physical & theoretical chemistry 2008
n. farahani h. aghaie

fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (pvc) matrixmembrane containing neutral carrier tetra phenyl porphyrin (tpp) ionophore. the addition ofsodium tetraphenylborate (natpb) and the plasticizer dbp has been found to substantiallyimprove the performance of the sensor. the best performance was obtained with the sensor havinga membrane of composition of tpp...

Hossein Naeimi Kobra Rabiei Mohammad Hossein Mashhadizadeh Mohammad Mazloum-Ardakani, Roya Mazidi

In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good  Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of  for perchlorate. The lim...

Journal: :international journal of environmental research 2011
h. bagheri sadeghi h. sid kalal h. hoveidi z. molavi n. adeli asl

a new cesium ion selective pvc membrane based on parent calix [4] arene was developed for potentiometric determination of cesium in environmental samples. the electrode based on p-5,11,17,23tetra(tertbutyl) 25,26,27,28-tetrahydroxy calix[4]arene(thc) as ionophor ,dibutyl phthalate (dbp)as plasticizer ,sodium tetra phenyl borate(natpb)and oleic acid as lipophilic salt and additive showed the ...

Journal: :journal of physical & theoretical chemistry 2011
m.h. fekri m. darvishpour e. baghdar

a poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a cr(iii) selective electrode. the electrode exhibits a good potentiometric response for cr(iii)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 m with a slope 19.5+0.5 mv/decade and low detectionlimit of 8.9 x 10-7 m. it has a fast response time < 15 s. the best perfo...

Journal: :journal of physical & theoretical chemistry 2015
h. aghaie m. h. felcri m. arvand k. zare m. aghaie

a pvc membrane cr(iii) ion selective electrode has been constructed using 2h-1,4-benzothioazine-2,3(4h)dione dioxime (btd) as membrane carrier. the influence of membrane composition on the electroderesponse was studied. the electrode exhibits a nernstian response over a cr(iii) concentration range of 1.0 x10 6 to 1.0>< 10-1 m (r = 0.99) with a slope of 19.5 ± 0.5 mv per decade of concentration,...

Journal: :international journal of nano dimension 0
sh. keyvan department of chemistry, faculty of science, islamic azad university, qeshm, iran. e. d. zobairi department of chemistry, faculty of science, islamic azad university, qeshm, iran. a. islamnezhad department of chemistry, faculty of science, islamic azad university, rasht, iran.

a nanocomposite membrane cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (etmoc) as a neutral ionophore. the electrode works properly. it responds to cu2+ ion with a sensitivity of 29.5 ± 0.2 mv/decade over the range 1.0 × 10−9 to 5.0 × 10−1m at ph 3.0-8.0. the limit of detection was 4.5 × ...

H. Aghaie M. Aghaie M. Giahi M. Pournaghdy

The preparation of polymer membrane selective to Iron(II) ion and its application to ion-selectiveelectrode is reported here. PVC membrane contains Iron–selective N-phenylaza-15-crown-5 asionophore. The membrane electrode is highly selective to Iron(II) ion and exhibit good linearresponse over a wide concentration range of 1.0 × 10-2 to 1.0 × 10-6 M with Nernstian slope of29.2 ± 0.6 mV per deca...

2009
D C Tiwari Rajeev Jain Shraddha Sharma

A composite polymer surface coated on a tin oxide offers dramatic improvement in the stability and sensitivity of voltammetric measurement of pyridostigmine bromide as compared to individual tin oxide, polyaniline or polypyrrole coated electrode. A linear current response was achieved with a detection limit of 1x10 M. The stability and morphology of the polymer surfaces were determined by therm...

Journal: :Journal of colloid and interface science 2006
Jitendra Mata Jaykumar Patel Nirmesh Jain Gautam Ghosh P Bahadur

We have examined the polymer-surfactant interaction in mixed solutions of the cationic surfactants, i.e., dodecyltrimethylammonium chloride, dodecyltrimethylammonium bromide, tetradecyltrimethylammonium bromide, hexadecyltrimethylammonium bromide, tetradecyltriphenylphosphonium bromide, and tetradecylpyridinium bromide and a semiflexible anionic polyelectrolyte carboxymethylcellulose in water a...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید