نتایج جستجو برای: blood glucose self

تعداد نتایج: 1320034  

Journal: :anesthesiology and pain medicine 0
fereshteh amiri pain research center, ahvaz jundishapur university of medical sciences, ahvaz, iran; department of anesthesiology, ahvaz jundishapur university of medical sciences, ahvaz, iran ali ghomeishi pain research center, ahvaz jundishapur university of medical sciences, ahvaz, iran; department of anesthesiology, ahvaz jundishapur university of medical sciences, ahvaz, iran seyed mohammad mehdi aslani pain research center, ahvaz jundishapur university of medical sciences, ahvaz, iran; department of anesthesiology, ahvaz jundishapur university of medical sciences, ahvaz, iran sholeh nesioonpour pain research center, ahvaz jundishapur university of medical sciences, ahvaz, iran; department of anesthesiology, ahvaz jundishapur university of medical sciences, ahvaz, iran sara adarvishi pain research center, ahvaz jundishapur university of medical sciences, ahvaz, iran; student research committee, nursing and midwifery school, ahvaz jundishapur university of medical sciences, ahvaz, iran; student research committee, nursing and midwifery school, imam khomeini hospital, ahvaz jundishapur university of medical sciences, azadegan ave., ahvaz, iran. tel: +98-6112220168, fax: +98-6112220168

conclusions blood glucose and hemodynamic changes caused by surgical stress were not significantly different between two groups. results there was not significantly difference between blood glucose level of both groups during 10 minutes before, 20 and 60 minutes after the intiation of anesthesia. heart rate changes in the general and spinal groups compared to the baseline level were decreased u...

2016
Ellen L Terry Yvette M Güereca Satin L Martin Jamie L Rhudy

OBJECTIVES Prior research has shown a relationship between blood glucose levels and some forms of self-regulation (eg, executive function), with low blood glucose levels associated with impaired self-regulation. Further, engagement in self-regulation tasks depletes blood glucose. Given these relationships, the present study examined whether blood glucose is associated with another form of self-...

2015
Joon Ho Hwang Yong-Hak Sohn Seong-Sil Chang Seung Yeon Kim

PURPOSE We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. METHODS Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ≤2,300 g or were ≤36 weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (...

Journal: :iranian journal of diabetes and obesity 0
seyyed omid mahdavi assistant professor, department of oral and maxillofacial medicine, dental faculty, shahid sadoughi university of medical science, yazd, iran sedighe hashemi dmd,graduated from , dental faculty, shahid sadoughi university of medical science ,yazd, iran najmeh sadat boostani postgraduate student of anesthesiology, department of anesthesiology, shahid sadoughi university of medical science,yazd, iran haleh zokaee postgraduate student of oral and maxillofacial medicine, department of oral and maxillofacial medicine, dental faculty, shahid sadoughi university medical science, yazd, iran

objective:fasting plasma glucose (fpg) analysis is the most importantmethod for detection and diagnosis of diabetes mellitus. due to difficulty and problems of this method for determination of glycemia in diabetic patients, recently the use of fasting salivary glucoseas a simple and non-invasive method to evaluate fpghas came into significant considerationof specialists. the aim of this study w...

2016
Gabriela Heiden Telo Martina Schaan de Souza Thais Stürmer Andrade Beatriz D’Agord Schaan

BACKGROUND Adherence to treatment has been defined as the degree to which a patient's behavior corresponds to medical or health advice; however, the most appropriate method to evaluate adherence to diabetes care has yet to be identified. We conducted analyses to compare adherence assessments and blood glucose monitoring measures with regard to their ability to predict glycemic control in adults...

Journal: :Diabetic medicine : a journal of the British Diabetic Association 2000
S Coster M C Gulliford P T Seed J K Powrie R Swaminathan

AIMS Self-monitoring of blood or urine glucose is widely used by subjects with Type 2 diabetes mellitus. This study evaluated the effectiveness of the technique at improving blood glucose control through a systematic review and meta-analysis. METHODS Randomized controlled trials were identified that compared the effects of blood or urine glucose monitoring with no self-monitoring, or blood gl...

Journal: :medical laboratory journal 0
maryam moradibinabaj msc of biochemistry, faculty of medicine mohadese namjoo msc of biochemistry mojgan nejabat msc of organic chemistry hamidreza joshaghani department of biochemistry

abstract        background and objective: the association of triglyceride/high density lipoprotein-cholesterol (tg/hdl-c) ratio with fasting serum insulin, which is an alternative method of insulin resistance (ir) measurement, is well-recognized. thus, the measurement of tg/hdl-c ratio is useful to determine both ir and dyslipidemia, which itself is a characteristic of individuals with ir. ther...

Journal: :Journal of Endocrinology, Metabolism and Diabetes of South Africa 2009

Journal: :Journal of Diabetes Science and Technology 2012

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید