نتایج جستجو برای: bladder and rectum dose

تعداد نتایج: 16879822  

2014
Moonkyoo Kong Seong Eon Hong Sung-Goo Chang

BACKGROUND This study is a report on the long-term analysis of acute and late toxicities for patients with localized prostate cancer treated with hypofractionated helical tomotherapy. METHODS From January 2008 through August 2013, 70 patients with localized prostate cancer were treated definitively with hypofractionated helical tomotherapy. The helical tomotherapy was designed to deliver 75 G...

A Mandal, A Sinha, N K Painuly N Singh, S Ahamed, S N Prasad, S Srivastava

Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...

2016
Zahra Siavashpour Mahmoud Reza Aghamiri Ramin Jaberi Naser ZareAkha Hamid Reza Dehghan Manshadi Christian Kirisits Mahbod Sedaghat

The purpose of this study was to investigate the concurrent effects of tandem length and bladder volume on dose to pelvic organs at risk (OARs) in HDR intracavitary brachytherapy treatment of cervical cancer. Twenty patients with locally advanced cervical cancer were selected for brachytherapy using Rotterdam applicators. The patients were CT scanned twice with empty and full bladder. Two treat...

Journal: :Journal of the Egyptian National Cancer Institute 2008
Yasir A Bahadur Mohamed E El-Sayed Zeinab H El-Taher Khaled O Zaza Belal A Moftah Ashraf H Hassouna Noor M Ghassal

INTRODUCTION Brachytherapy is an integral part in the treatment of cervical uteri cancer patients. Orthogonal treatment planning is the standard mode of calculation based on reference points. Introduction of the innovative 3-D computer based treatment planning allows accurate calculation based on volumetric information as regards the target volume and organs at risk (OAR). Also provide dose vol...

2015
Ozan C. Guler Cem Onal Ibrahim Acibuci

PURPOSE To investigate dosimetric effects of bladder distention on organs at risk (OARs) during treatment of endometrial cancer using 3D image-based planning of postoperative vaginal vault brachytherapy (BRT). MATERIAL AND METHODS Fifteen patients with early-stage endometrial cancer were studied, each undergoing adjuvant BRT of vaginal vault via 3.5 cm diameter cylinder. As treatment, 25 Gy i...

2014
Goran Marosevic Dzenita Ljuca Hasan Osmic Semir Fazlic Oliver Arsovski Dusan Mileusnic

BACKGROUND The aim of the study was to examine on the CT basis the inter-application displacement of the positions D0.1cc, D1cc and D2cc of the brachytherapy dose applied to the bladder and rectum of the patients with inoperable cervical cancer. PATIENTS AND METHODS This prospective study included 30 patients with cervical cancer who were treated by concomitant chemo-radiotherapy. HDR intraca...

2014
Santam Chakraborty Firuza D Patel Vijay M Patil Arun S Oinam Suresh C Sharma

Background. Quantifying the interfraction dose variations in the organs at risk (OAR) in HDR intracavitary brachytherapy (HDR ICBT). Methods. Rectum and bladder were contoured in 44 patients of cervical carcinoma on CT after each fraction of HDR ICBT (9 Gy/2 fractions). Interfraction dose variations (VARact) were calculated. Rigid image registration of consecutive fraction images allowed quanti...

2013
Niladri B. Patra Kazi S. Manir Swapnendu Basu Jyotirup Goswami Apurba K. Kabasi Shyamal K. Sarkar

PURPOSE Distension and shape of urinary bladder may vary during intracavitary brachytherapy (ICBT) for cervical cancer, significantly affecting doses to bladder, rectum, sigmoid colon and small intestine and consequently late radiation toxicities. This study is to evaluate the effects of different fixed volume bladder distention on dosimetry, assessed by three dimensional image based planning, ...

Journal: :Asian Pacific journal of cancer care 2022

Background: Present study compares two high-dose-rate intracavitary brachytherapy (ICBT) planning methods using two-dimensional orthogonal radiography and three-dimensional computed tomography (3D-CT) with regard to dose target volume organs at risk (OAR) in carcinoma cervix. Methodology: ICBT plans for 22-patients were compared 2D techniques. treatment generated 2D-orthogonal images was prescr...

2013
Sang Gyu Ju Seung Jae Huh Jung Suk Shin Won Park Heerim Nam Sunhyun Bae Dongryul Oh Chae-Seon Hong Jin Sung Kim Youngyih Han Doo Ho Choi

This study sought to evaluate the differential effects of bladder distention on point A-based (AICBT) and three-dimensional conformal intracavitary brachytherapy (3D-ICBT) planning for cervical cancer. Two sets of CT scans were obtained for ten patients to evaluate the effect of bladder distention. After the first CT scan, with an empty bladder, a second set of CT scans was obtained with the bl...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید