نتایج جستجو برای: beamnrc
تعداد نتایج: 127 فیلتر نتایج به سال:
This study provided baseline data required for a greater project, whose objective was to design a new Elekta electron collimation system having significantly lighter electron applicators with equally low out-of field leakage dose. Specifically, off-axis dose profiles for the electron collimation system of our uniquely configured Elekta Infinity accelerator with the MLCi2 treatment head were mea...
Introduction: The received dose to the surface of tumor bed is one of the main issues in beast intraopeative radiotherapy (IORT). Totally, the administered dose to the surface is usually lower than that of radiotherapy reference point (distal end of tumor bed). Employing a buildup bolus can effectively increase the surface dose and therefore, eliminate such created cold points ...
Abstract: Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...
introduction: gafchromic ebt films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (tpss). their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. this study was designed to evaluate the dosimetric parameters of...
Introduction: Several studies have discussed to the electron contamination caused by the air column between the head of linac and patient for photon beams. Since it is not possible to measure the electron contamination with practical dosimetry, the Monte Carlo technique is an appropriate and accurate choice to calculate particle flounce in radiation therapy. The purpose of t...
Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator. Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...
In this study, the MAGIC- f polymer gel was used to determine the absorbed dose by external radiation therapy. The MAGIC- f gel was made under normal pressure and temperature conditions and irradiated with a Siemens 6MV linear accelerator at 10 × 10 cm2 and at a depth of 10 cm. While simulating the head of the accelerator unit by the Monte Carlo method with BEAMnrc code, the percentage depth do...
The treatment of large tumors such as sarcomas with intra-operative radiotherapy using a Mobetron is often complicated because of the limited field size of the primary collimator and the available applicators (max Ø100 mm). To circumvent this limitation a prototype rectangular applicator of 80 x 150 mm(2) was designed and built featuring an additional scattering foil located at the top of the a...
Stopping power ratios sw,air for electron beams produced by the NOVAC7® IORT accelerator were calculated at different depths in water by the SPRRZnrc Monte Carlo code. As input for the SPRRZnrc code a phase-space data file obtained for any beam by the BEAMnrc code was used. The calculated stopping power ratios were compared with those recommended by the IAEA dosimetry protocols TRS-381 and TRS-...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید