نتایج جستجو برای: atrial cardiac catheterization septal occluder device

تعداد نتایج: 1021095  

Journal: :Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese 2012
Petros S Dardas Vlasis Ninios Nikos Mezilis Efstratios K Theofilogiannakos Dimitris Tsikaderis Vassilis Thanopoulos

We present the case of a patient who underwent a percutaneous secundum atrial septal defect (ASD II) closure with an undersized septal occluder device. One week and one month later she experienced two transient ischemic attacks. Three-dimensional transesophageal echocardiography (TEE) revealed a residual patent foramen ovale (PFO) with a positive Valsalva bubble test. She underwent a second pro...

Journal: :Heart Rhythm 2023

Diastolic mitral regurgitation (DMR) may occur due to an increased left ventricular (LV) cavity pressure compared the atrial (LA) pressure. This with bradycardia when diastolic filling time is increased. In our case, patient was found have blocked bigeminal premature contractions (PACs) causing leading regurgitation. N/A A 58-year-old woman presented one week history of shortness breath, paroxy...

Journal: :Circulation. Cardiovascular interventions 2012
Derek A Williams Yoshio Ootaki Michael D Quartermain

A 4-year-old asymptomatic girl presented for elective transcatheter closure of her ostium secundum atrial septal defect (ASD). Her examination revealed a fixed split second heart sound with a 2/6 systolic ejection murmur at the left upper sternal border and a right ventricular lift. Transthoracic echocardiogram demonstrated a 15-mm secundum ASD with a mildly dilated right ventricle. The left co...

Journal: :International Surgery Journal 2023

Atrial septal defect (ASD) is one of the most common types congenital heart defects. Percutaneous closure ASD relatively safe and accepted as an alternative to surgery. However, device-related complications can occur rarely. Embolization Amplatzer atrial occluder (ASO) major complication percutaneous device closure. The author presents a case early embolization ASO into left atrium, which remov...

Journal: :Circulation 1990
E B Sideris S E Sideris J P Fowlkes R L Ehly J E Smith R E Gulde

The feasibility and safety of transvenous closure of atrial septal defects by a new device was tested in 20 piglets, in which atrial septal defects were created by foramen ovale dilatation with angioplasty balloons. The device was small enough to be introduced in a 7F or 8F sheath, and it measured 20-25 mm. It has no hooks and consists of a foam occluder from the left atrium and a counter-occlu...

2015
Mashail Alobaidan A Saleem H Abdo J Simpson

UNLABELLED The case report of a 15-year-old patient with an unusual form of atrial septal defect is described. Echocardiography showed separation of the secundum and primum atrial septums due to abnormal posterior and leftward attachment of the primum septum into the roof of the left atrium. The morphology has been variably described as a 'double' atrial septum or 'spiral' atrial septal defect....

Journal: :the journal of tehran university heart center 0
mustafa karaçelik department of pediatric cardiac surgery, dr. behçet uz children’s hospital, izmir, turkey. pelin öztürk department of pediatric cardiac surgery, dr. behçet uz children’s hospital, izmir, turkey. onur doyurgan department of pediatric cardiac surgery, dr. behçet uz children’s hospital, izmir, turkey. uğur karagöz department of pediatric cardiac surgery, dr. behçet uz children’s hospital, izmir, turkey. murat muhtar yilmazer department of pediatric cardiology, dr. behçet uz children’s hospital, izmir, turkey. timur meşe department of pediatric cardiology, dr. behçet uz children’s hospital, izmir, turkey.

today, congenital heart diseases may be treated without surgery through advances in interventional cardiology. however, complications such as infection and thrombus formation may develop due to foreign materials used during these procedures. surgical intervention may be required for the removal of the device utilized for the procedure. in this case report, we present the surgical treatment of a...

2012
Fatemeh Nabavizadeh Navin C Nanda Amitoj Singh Carmen Mateescu

Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...

Journal: :Singapore medical journal 2012
P K Goel A Kapoor

This case report describes a modification in the technique of atrial septal device closure in a patient with atrial septal defect (ASD) with associated atrial septum aneurysm and significant left-to-right shunt through multiple perforations. Graded balloon dilatation of the aneurysm was performed in this patient, as a preamble to successful deployment of a single large Amplatzer atrial septal o...

Journal: :Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology 2018
Yusuf I Alihanoglu Dogu I Kilic Bekir S Yildiz Bilgin Emrecan Harun Evrengul

A 21-year-old male with a 27-mm atrial septal defect (ASD) underwent an uneventful percutaneous device closure using a 28-mm Ultrasept ASD Occluder with super-low profile (Cardia, Inc., USA) under transoesophageal echocardiography (TEE) guidance. We particularly favoured this kind of occluder device due to the possible future need for catheter atrial septostomy in such a young patient. The use ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید