نتایج جستجو برای: asymmetric biphasic waveform

تعداد نتایج: 92506  

Journal: :Circulation 2000
S R Shorofsky M R Gold

BACKGROUND The mechanism by which biphasic waveforms improve defibrillation efficacy is unclear. In addition, the optimal shape of the biphasic waveforms remains controversial. Animal experiments suggest that prolonging the duration of the second phase longer than the first worsens defibrillation thresholds (DFT). The purpose of this study was to determine the strength-duration relation for the...

Journal: :Circulation 2000
J Huang B H KenKnight D L Rollins W M Smith R E Ideker

BACKGROUND It has been reported that triphasic defibrillation waveforms cause less myocardial injury than biphasic waveforms. This study compared the defibrillation thresholds (DFTs) of triphasic and biphasic waveforms. METHODS AND RESULTS ++DFTs were determined for a transvenous lead system and a 300-microF-capacitor defibrillator. In 8 pigs (group 1), DFTs were determined for 5 triphasic wa...

2005
William M. Smith

Background. The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. Methods and Results. Sustained atrial fibrillation couldbe induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each par...

Journal: :Circulation 1993
R A Cooper C A Alferness W M Smith R E Ideker

BACKGROUND The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. METHODS AND RESULTS Sustained atrial fibrillation could be induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each pa...

Journal: :ACP journal club 2003
Edward Havranek

I n t e r v e n t i o n Patients were allocated to impedance-compensated truncated exponential biphasic shocks (n = 96) or damped sine wave monophasic shocks (n = 107). Patients received up to 5 shocks: 100 joules (J), 150 J, 200 J, a fourth shock at maximum output for the initial waveform (200 J biphasic, 360 J monophasic), and a final crossover at maximum output of the alternate waveform. M a...

Journal: :Circulation 1996
G H Bardy F E Marchlinski A D Sharma S J Worley R M Luceri R Yee B D Halperin C L Fellows T S Ahern D A Chilson D L Packer D J Wilber T A Mattioni R Reddy R A Kronmal R Lazzara

BACKGROUND The most important factor for improving out-of-hospital ventricular fibrillation survival rates is early defibrillation. This can be achieved if small, lightweight, inexpensive automatic external defibrillators are widely disseminated. Because automatic external defibrillator size and cost are directly affected by defibrillation waveform shape and because of the favorable experience ...

Journal: :Circulation 1998
G P Walcott S B Melnick F W Chapman J L Jones W M Smith R E Ideker

BACKGROUND Recently, interest has arisen in using biphasic waveforms for external defibrillation. Little work has been done, however, in measuring transthoracic defibrillation efficacy after long periods of ventricular fibrillation. In protocol 1, we compared the efficacy of a quasi-sinusoidal biphasic waveform (QSBW), a truncated exponential biphasic waveform (TEBW), and a critically damped si...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید