نتایج جستجو برای: anion selective electrode

تعداد نتایج: 291411  

Journal: :journal of physical & theoretical chemistry 2015
h. aghaie m. h. felcri m. arvand k. zare m. aghaie

a pvc membrane cr(iii) ion selective electrode has been constructed using 2h-1,4-benzothioazine-2,3(4h)dione dioxime (btd) as membrane carrier. the influence of membrane composition on the electroderesponse was studied. the electrode exhibits a nernstian response over a cr(iii) concentration range of 1.0 x10 6 to 1.0>< 10-1 m (r = 0.99) with a slope of 19.5 ± 0.5 mv per decade of concentration,...

Journal: :international journal of nano dimension 0
sh. keyvan department of chemistry, faculty of science, islamic azad university, qeshm, iran. e. d. zobairi department of chemistry, faculty of science, islamic azad university, qeshm, iran. a. islamnezhad department of chemistry, faculty of science, islamic azad university, rasht, iran.

a nanocomposite membrane cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (etmoc) as a neutral ionophore. the electrode works properly. it responds to cu2+ ion with a sensitivity of 29.5 ± 0.2 mv/decade over the range 1.0 × 10−9 to 5.0 × 10−1m at ph 3.0-8.0. the limit of detection was 4.5 × ...

H. Aghaie M. Aghaie M. Giahi M. Pournaghdy

The preparation of polymer membrane selective to Iron(II) ion and its application to ion-selectiveelectrode is reported here. PVC membrane contains Iron–selective N-phenylaza-15-crown-5 asionophore. The membrane electrode is highly selective to Iron(II) ion and exhibit good linearresponse over a wide concentration range of 1.0 × 10-2 to 1.0 × 10-6 M with Nernstian slope of29.2 ± 0.6 mV per deca...

Journal: :Journal of Solid State Electrochemistry 2021

Abstract Commercial resin microbeads are widely applied in ion exchange and extraction. Here, a single anion-selective phosphate binding microbead (FerrIX™) is mounted into an epoxy membrane investigated by 4-electrode voltammetry impedance spectroscopy. Anion transport properties observed to dominate associated with three distinct potential domains: (I) low bias ohmic domain (dominant at high ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2006
Wen-Ju Xu Ya-Qin Chai Ruo Yuan Lan Xu Su-Li Liu

In this paper, a new PVC-based liquid-membrane anion-selective electrode based on a copper(II) of N,N'-bis(salicylidene)-1,2-bis(p-aminophenoxy)ethane tetradentate complex (Cu(II)BBAP) is described, which displays a preferential potentiometric response to iodide ion at pH 2.0 and an anti-Hofmeister selectivity sequence: I->SCN->ClO4->NO2->H2PO4->NO3->SO4(2-)>Br->Cl-. The electrode exhibits a ne...

Journal: :The Plant journal : for cell and molecular biology 2004
Mark A Messerli Peter J S Smith Robert C Lewis Kenneth R Robinson

Microelectrodes, made from a Cl(-)-selective liquid ion exchanger previously used to measure putative Cl- fluxes in Lilium longiflorum pollen tubes, were characterized. The electrodes were poorly selective, possessing only about 10-fold selectivity for Cl- over other anions tested. They had only 2.4-fold selectivity for Cl- over the anionic form of the H+ buffer, MES, indicating that the electr...

Journal: :analytical and bioanalytical chemistry research 2014
a. shokrollahi a. abbaspourb a. naghashian haghighia a. h. kianfar

a new al(iii) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (pvc) matrix is coated on platinum wire to determine trace amounts of al(iii) ion in various samples. the sensor exhibits a good response for al(iii) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 m  with nernstian slope of 19.64 ± 0.15 mv decade-1...

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaei masood giahi majjid arvand mehran aghaei

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

Journal: :journal of physical & theoretical chemistry 2007
m. aghaie m. h. fekri m. giahi e. baghdar s. farhadi

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :journal of physical & theoretical chemistry 2011
m. kia a. islamnezhad sh. shariati

in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...

نمودار تعداد نتایج جستجو در هر سال