نتایج جستجو برای: aliii selective electrode

تعداد نتایج: 259980  

Journal: :journal of physical & theoretical chemistry 2004
h. aghaie m. giahi1 giahi m. aghaei m. arvand3

we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...

Journal: :journal of physical and theoretical chemistry 0
m. h. fekri - m. darvishpour -

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n&apos;1,n&apos;2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best perfo...

Journal: :journal of physical and theoretical chemistry 0
m. aghaie - m. h. fekri - m. giahi - e. baghdar - s. farhadi -

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :nanochemistry research 0
abbas afkhami faculty of chemistry, bu-ali sina university, hamedan, iran mahdi moradi faculty of chemistry, bu-ali sina university, hamedan, iran atousa bahiraei faculty of chemistry, bu-ali sina university, hamedan, iran tayyebeh madrakian faculty of chemistry, bu-ali sina university, hamedan, iran

in the present study, a new chemically modified carbon paste electrode (cpe) is constructed for rapid, accurate, simple, highly sensitive, and selective determination of mo (vi) using differential pulse voltammetry. the electrode was prepared using magnetic nickel zinc ferrite nanocomposite (ni0.5zn0.5fe2o4), as the modifier in cpe (ni0.5zn0.5fe2o4/cpe). mo (vi) was determined after preconcentr...

Journal: :journal of physical & theoretical chemistry 2007
masoud giahi mohammad ali bagherinia azin azari

sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of vo2+ in aqueous solutions. the sol-gel and pvcmembrane electrodes exhibited linear response with nernstian slopes of 29.3 and 28.4 mv perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

Abbas Afkhami, Atousa Bahiraei Mahdi Moradi Tayyebeh Madrakian,

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

In this study a simple, highly sensitive, and selective electrochemical method was developed for determination of the low concentration curcumin (CUR) using a poly(vanillin-co-caffeic acid) p(Van-CA) modified platinum electrode. Electrode modification was carried out electrochemically with cyclic voltammetry (CV) method. For this purpose; a solution of 6 mM vanillin (Van) and 6 mM caff...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2007
Fuping Zhang Min Zhang Jiongjia Cheng Li Yang Ming Ji Shuping Bi

In this paper, we firstly report the direct voltammetric recognition and determination of dopamine (DA) by using Al(III)-DA complexes at the hanging mercury drop electrode (HMDE). A new sensitive cathodic peak of Al(III)-DA can be detected at -900 mV (vs. SCE) in 0.1 M NH(4)Cl-NH(3).H(2)O-0.1 M KCl buffer solution at pH 8.5. This unique -900 mV cathodic peak arises from the specific interaction...

Journal: :journal of the iranian chemical research 0
ali benvidi department of chemistry, faculty of science, yazd university, yazd, iran mehdi elahizadeh department of chemistry, faculty of science, yazd university, yazd, iran hamid reza zare, department of chemistry, faculty of science, yazd university, yazd, iran rasoul vafazadeh department of chemistry, faculty of science, yazd university, yazd, iran

an iodide ion-selective pvc membrane sensor based on copper (π)-bis-nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mv per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol l-1,...

Forogh Adhami Leila Hajiaghababaei Saeid Takalou

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید