High tall buildings are more susceptible to dynamic excitations such as wind and seismic excitations. In this paper, design procedure and some current applications of tuned mass damper (TMD) were studied. TMD was proposed to study response of 20 storey height building to seismic excitations using time history analysis with and without the TMD. The study indicates that the response of structur...
ISSN 2277-5056 | © 2012 Bonfring Abstract--Tall buildings cater to the need for increased workspace with a reduced footprint, enhance the skyline, and image and increase the prestige of a city. Tall buildings also tend to intercept upper level high velocity winds and deflect them down to ground level, giving rise to conditions that could be unpleasant or even dangerous to pedestrians. Such acce...
Tall building can vibrate in both the directions of Along wind and Across wind caused by the flow of wind. Modern Tall buildings designed to satisfy lateral drift requirements, still may oscillate excessively during wind storm. These oscillations can cause some threats to the tall building as buildings with more and more height becomes more vulnerable to oscillate at high speed winds. Sometimes...
Seismic pounding occurs as a result of lateral vibration and insufficient separation distance between two adjacent structures during earthquake excitation. This research aims to evaluate the stochastic behavior of adjacent structures with equal heights under earthquake-induced pounding. For this purpose, many stochastic analyses through comprehensive numerical simulations are carried out. About...
The design of tall buildings, while concerned with efficiently and effectively carrying the anticipated loads imposed upon the structures, is largely concerned with serviceability and habitability issues. The latter issue may still require attention, even for buildings designed to meet lateral drift requirements (Kareem et al. 1999). As such, structural accelerations, as a function of return pe...
Open kitchens have been designed for many small residential units in tall buildings in Southeast Asia. This open design, without enclosing the kitchen with fire resisting walls has failed to comply with building fire safety codes in places like Hong Kong. Performance-based design was adopted to determine fire safety provisions. Gas cookers with flames are not allowed. Additional fire protection...
Using energy absorption systems in the structures with malfunctioning components is of paramount importance. By absorbing the seismic energy, these systems help the components of the structure to remain resilient during earthquake. In the present study, viscous dampers were applied in order to enhance the reactions of tall building with belt truss. To assess the response of a structure under e...