نتایج جستجو برای: 6mv photons
تعداد نتایج: 47464 فیلتر نتایج به سال:
Purpose Monte Carlo (MC) models of radiotherapy beams can be used as a comparison benchmark for other dose calculation methods. In any such comparison process, the degree to which an identified deviation represents an actual error will depend upon the accuracy of the benchmark. As part of an ongoing dosimetric study, we have sought to model the standard Varian Clinac 6MV beam as accurately as p...
At the beginning of thermonuclear ignition in fusion plasma, the bremsstrahlung radiation is dominant phenomenon, the photons distribution function is Planckian and plasma is considered as optically thick one. But at a certain energy, the bremsstrahlung radiation and Compton scattering losses rates become equal and plasma makes a transition from optically thick to optically thin and photons dis...
background: radiation therapy uses high-energy radiation to kill cancer cells. photoneutron contamination and induced radioactivity of high energy therapeutic photon beams are considered as the main source of occupational exposure to radiation therapists who works with linear accelerators operating above 10 mv. materials and methods: the gamma dose rates were measured after termination of diff...
BACKGROUND Critical macromolecules of cells such as DNA are in exposure to damage of free radicals that induced from the interaction of ionizing radiation with biological systems. Selenium and vitamin-E are natural compounds that have been shown to be a direct free radical scavenger. The aim of this study was to investigate the radioprotective effect of selenium and vitamin-E separately and syn...
in this work we investigate the thermal entanglement between two-level atoms and photons in a nonlinear cavity. we consider intensity-dependent couplings and calculate the negativity, as a measure of atom-photonentanglement. the cavity is assumed to be at a temperature t, so that all number of photons, and at the same time, both atomic states, with definite probabilities, are present. we then d...
BACKGROUND The accuracy of the two dose calculation engines available for RapidArc planning (both released for clinical use) is investigated in comparison to the COMPASS data. METHODS Two dose calculation algorithms (Acuros-XB and Anisotropic Analytic Algorithm (AAA)) were used to calculate RA plans and compared to calculations with the Collapsed Cone Convolution algorithm (CC) from the COMPA...
BACKGROUND To report about initial clinical experience in radiation treatment of carcinoma of prostate with volumetric modulated arcs with the RapidArc (RA) technology. METHODS Forty-five patients with a median age of 72 +/- 3, affected by prostate carcinoma (T1c: 22 patients, T2a-b: 17 patients, T3a-b: 6 patients. N0: 43 patients, N1-Nx: 2 patients, all M0), with initial PSA of 10.0 +/- 3.0 ...
background: attenuation coefficient (μ) plays an important role in calculations of treatment planning systems, as well as determination of dose distributions in external beam therapy, dosimetry, protection, phantom materials and industry. so, its exact measurement or calculation is very important. the aim of this study was to evaluate the μ in different points in the water phantom analytically ...
Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8±0.35 at 25.5keV (50kVp) peaking at 12.1±0.5 at 54keV (125kVp) to 0.975±0.03 at 2300keV (10MV) when norm...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید