نتایج جستجو برای: 32p applicator

تعداد نتایج: 5150  

2012
Bishan Basu Swapnendu Basu Bikramjit Chakraborti Suman Ghorai Phalguni Gupta Sajal Ghosh Koushik Ghosh J. Jayanti

PURPOSE During intracavitary brachytherapy (ICBT) for cervical cancer, the choice of applicator system remains rather arbitrary. However, as the applicator geometry may play an important role in dose distribution, thereby improving the therapeutic ratio, this study was conducted to compare the Manchester-style and Fletcher-style applicator systems. MATERIAL AND METHODS After completion of EBR...

Journal: :Brachytherapy 2003
John C Roeske Christina Lund Charles A Pelizzari Xiaochuan Pan Arno J Mundt

PURPOSE To evaluate a method of reducing computed tomography (CT) metal artifacts due to the Fletcher-Suit applicator. METHODS AND MATERIALS We apply a projection-interpolation algorithm to CT images containing artifacts from the brachytherapy applicator. Regions of projection data containing the applicator are interpolated, removing the metal from the projections. A new image is then reconst...

Journal: :Asian Pacific journal of cancer prevention : APJCP 2015
Dan Shi Ming-Yuan He Zhi-Peng Zhao Ning Wu Hong-Fu Zhao Zhi-Jian Xu Guang-Hui Cheng

BACKGROUND For brachytherapy of cervical cancer, applicator shifts can not be avoided. The present investigation concerned Utrecht interstitial applicator shifts and their effects on organ movement and DVH parameters during 3D CT-based HDR brachytherapy of cervical cancer. MATERIALS AND METHODS After the applicator being implanted, CT imaging was achieved for oncologist contouring CTVhr, CTVi...

Journal: :Physics in medicine and biology 2014
Gabriel Paiva Fonseca Guillaume Landry Shane White Michel D'Amours Hélio Yoriyaz Luc Beaulieu Brigitte Reniers Frank Verhaegen

Accounting for brachytherapy applicator attenuation is part of the recommendations from the recent report of AAPM Task Group 186. To do so, model based dose calculation algorithms require accurate modelling of the applicator geometry. This can be non-trivial in the case of irregularly shaped applicators such as the Fletcher Williamson gynaecological applicator or balloon applicators with possib...

2006
Nagarajan Vivekanandan Bhuvana Kunjithapatham Nithya Kanakavelu Balakrishnan Shankarrao Irde Lakshmanan Alathurmadam Vaidyanathan

In CT anatomy-based inverse treatment planning of interstitial high-dose rate (HDR) brachytherapy planning, the planning target volume (PTV) delineated by the radiation oncologist includes the applicator volume. The applicator volume can be eliminated with the help of two methods: one based on Boolean operations and the other using the erasing option of the application software. Both methods ar...

Journal: :iranian journal of radiation research 0
m.r. teimoori sichani department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran m. amoui department of nuclear medicine, shahid beheshti university of medical science, tehran, iran sh. akhlaghpoor noor medical imaging center, tehran, iran m. hosntalab department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

background: in this study, quantitative 32p bremsstrahlung planar and spect imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate dosimetry in clinical practice. materials and methods: ct, planar and spect bremsstrahlung images of jaszczak phantom containing a known activity of 32p were acquired. in addition, phanto...

Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive sp...

2017
Bikramjit Chakrabarti Somapriya Basu-Roy Sanjay Kumar Kar Sounik Das Annesha Lahiri

Purpose This study is intended to compare dose-volume parameters evaluated using different forward planning- optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose-rate (HDR) fractionation schedules. Material and ...

2005
Slobodan Devic Té Vuong Belal Moftah

High-dose rate endorectal brachytherapy (HDR-EBT) is mainly used as a palliative treatment modality. In this paper, we compare dosimetry distributions for a single-channel catheter (Miami) applicator with distributions of the inflatable multichannel (Novi Sad) endorectal applicator. The comparisons were made with respect to dose coverage to the clinical tumor volume as well as to the bladder, r...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید