نتایج جستجو برای: راکتور sbr

تعداد نتایج: 3924  

Journal: :Brain : a journal of neurology 1998
H Miwa C Nohara M Hotta Y Shimo K Amemiya

The somatosensory-evoked blink response (SBR) is a newly identified blink reflex elicited by electrical stimulation of peripheral nerves. The present study was performed to investigate the physiological mechanism underlying the SBR elicited by median nerve stimulation in normal subjects. The peripheral afferents responsible for the SBR included low-threshold cutaneous fibres. In the SBR-positiv...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه رازی - پژوهشکده فنی و مهندسی 1392

چکیده پساب های تولید شده توسط بسیاری از فعالیت های صنعتی، حاوی ترکیبات آلی مقاومی هستند که تصفیه آن ها از طریق فرایندهای بیولوژیکی به تنهایی دشوار است. معمولا استفاده از یک روش اضافی برای حذف این ترکیبات لازم است. هدف از این مطالعه استفاده از دو راکتور هوازی sbr در مقیاس آزمایشگاهی است که به صورت سری قرار گرفته اند و با فرایند ازناسیون به منظور حذف cod از پساب کارخانه نوشابه سازی ترکیب شده اند...

2016
Caspar Langenbach Ruth Campe Sebastian F. Beyer André N. Mueller Uwe Conrath

Phakopsora pachyrhizi is a biotrophic fungus provoking SBR disease. SBR poses a major threat to global soybean production. Though several R genes provided soybean immunity to certain P. pachyrhizi races, the pathogen swiftly overcame this resistance. Therefore, fungicides are the only current means to control SBR. However, insensitivity to fungicides is soaring in P. pachyrhizi and, therefore, ...

2011
S. Vigneswaran D. S. Chaudhary

1. Background 2. The SBR technology for wastewater treatment 3. Physical description of the SBR system 3.1 FILL Phase 3.2 REACT Phase 3.3 SETTLE Phase 3.4 DRAW or DECANT Phase 3.5 IDLE Phase 4. Components and configuration of SBR system 5. Control of biological reactions through operating strategies 6. Design of SBR reactor 7. Costs of SBR 8. Case studies 8.1 Quakers Hill STP 8.2 SBR for Nutrie...

Journal: :Clinical and vaccine immunology : CVI 2014
Weiwei Zhao Hans Minderman Michael W Russell

Intragastric immunization with recombinant chimeric immunogen, SBR-CTA2/B, constructed from the saliva-binding region (SBR) of Streptococcus mutans antigen AgI/II and the A2/B subunits of cholera toxin (CT) induces salivary and circulating antibodies against S. mutans that protect against dental caries. We previously found that SBR-CTA2/B activated dendritic cells (DC) in the Peyer's patches (P...

Journal: :Chemosphere 2009
Tania Datta Yanjie Liu Ramesh Goel

The treatment and disposal of excess sludge has been a rising challenge for wastewater treatment plants worldwide. In this study, simultaneous sludge reduction and nutrient removal was evaluated in laboratory scale sequencing batch reactors (SBRs). Two SBRs were operated alongside for a duration of 370d. One SBR was operated to achieve nutrient removal (control-SBR) at 10d solids retention time...

2016
Andrea Marchi Vlasta Bari Beatrice De Maria Murray Esler Elisabeth Lambert Mathias Baumert Alberto Porta

We propose a sympathetic baroreflex (sBR) sequence method for characterizing sBR from spontaneous beat-to-beat fluctuations of muscle sympathetic nerve activity (MSNA) and diastolic arterial pressure (DAP). The method exploits a previously defined MSNA variability quantifying the fluctuations of MSNA burst rate. The method is based on the detection of MSNA and DAP sequences characterized by the...

2015
Iman Akef Khowailed Jerrold Petrofsky Everett Lohman Noha Daher

BACKGROUND The aim of this study was to examine the effects of a 6-week training program of simulated barefoot running (SBR) on running kinetics in habitually shod (wearing shoes) female recreational runners. MATERIAL AND METHODS Twelve female runners age 25.7 ± 3.4 years gradually increased running distance in Vibram FiveFingers minimal shoes over a 6-week period. The kinetic analysis of tre...

2007
C M Wong

TOP ABSTRACT METHODS RESULTS DISCUSSION REFERENCES Background: Two devices are available for making transcutaneous estimates of serum bilirubin (SBR): the Minolta AirShields JM102 and the new SpectRx BiliCheck. Objectives: (a) To measure how well the readings produced by these devices agree with SBR measured in the laboratory; (b) to estimate for each device, the proportion of infants with clin...

Journal: :Archives of disease in childhood. Fetal and neonatal edition 2002
C Mae Wong P J E van Dijk I A Laing

BACKGROUND Two devices are available for making transcutaneous estimates of serum bilirubin (SBR): the Minolta AirShields JM102 and the new SpectRx BiliCheck. OBJECTIVES (a) To measure how well the readings produced by these devices agree with SBR measured in the laboratory; (b) to estimate for each device, the proportion of infants with clinical jaundice who would require blood sampling if t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید