نتایج جستجو برای: دستگاه orbscan ii
تعداد نتایج: 610793 فیلتر نتایج به سال:
PURPOSE To evaluate and compare anterior chamber depth (ACD) measurements using Orbscan II (Bausch & Lomb, Rochester, NY) and IOLMaster (Carl Zeiss Meditec AG, Jena, Germany). METHODS In this prospective clinical study, the authors measured ACD of 145 phakic eyes of 30 healthy volunteers and 115 patients using Orbscan II and IOLMaster. Average patient age was 52.9+/-19.4 (range 16 to 87) year...
PURPOSE We classified the Orbscan anterior elevation maps in normal eyes (under myopic, emmetropic and hyperopic conditions) and in those after myopic refractive surgery. We did this classification to demonstrate how Orbscan anterior elevation maps are useful in screening for the existence and extent of previous myopic refractive surgery. Such a classification can help clinicians interpret preo...
A 33-year-old man seeking refractive surgery presented with refractive error of -1.75 -4.0×20° in the right and -0.75 -2.5×170° in his left eye in January 2009; best spectacle-corrected visual acuity (BSCVA) was 20/25+ and 20/20respectively. All ocular examinations were unremarkable and family history for keratoconus was negative. He had previously obtained consultation for refractive surgery i...
purpose: to compare thickness of central cornea measured using pentacam, orbscan ii, and ultrasound pachymeter methods: patients with no history of corneal diseases or systemic diseases affecting eyes, who did not wear contact lens or use eye medications, and who with no previous history of corneal surgery were selected for this study. central corneal thickness (cct) was measured by three metho...
purpose: to compare orbscan ii (o ii) and ultrasound (us) pachymetry in normal and post-lasik eyes. methods: in a comparative prospective study, central corneal thickness (cct) was measured in 168 eyes of 84 normal subjects and 42 eyes without corneal opacity of 21 post-lasik patients by o ii and us. paired t test was used to identify significant differences between the two methods and pearson ...
PURPOSE To introduce a new convenient and accurate method to measure the angle kappa using ultrasound biomicroscopy (UBM) and corneal topography. METHODS Data from 42 eyes (13 males and 29 females) were analyzed in this study. The angle kappa was measured using Orbscan II and calculated with UBM and corneal topography. The angle kappa of the dominant eye was compared with measurements by Orbs...
BACKGROUND Central corneal thickness (CCT) can be measured by using contact and non-contact methods. Ultrasound pachymetry (US pachymetry) is a contact method for measuring CCT and is perhaps the most commonly used method. However, non-contact methods like scanning slit topography (Orbscan II), slit-lamp optical coherence tomography (SL-OCT), and specular microscopy are also used. Not many stud...
AIMS To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). METHODS Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. RESULTS Three...
Aims: To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). Methods: Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. Results: Three ...
PURPOSE To determine the sensitivity and specificity of anterior and posterior corneal elevation parameters as determined by Orbscan II (Bausch and Lomb, Rochester, NY, USA) in discriminating between (sub) clinical keratoconus (KCN) and normal corneas. METHODS This prospective case-control study included 28 eyes with subclinical KCN, 65 with clinical KCN and 141 normal corneas. Anterior and p...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید