نتایج جستجو برای: transverse measurement

تعداد نتایج: 483243  

Journal: :Physical Review Letters 2021

Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution electron bunch. In some cases, if only one parameter is unknown, this can be determined from measured magnitude these fluctuations. Letter, we report an absolute measurement (no free parameters or calibration) small vertical emittance (5--15 nm r...

1999
X. - M. Zhu

Using the random matrix theory we demonstrate explicitly the insensitivity of the transverse force on a moving vortex to non-intrinsic and non-magnetic impurities in a superconductor. The Berry phase acquired by a moving vortex suggests that the total transverse force on a moving vortex is proportional to the superfluid density at zero temperature, irrespective whether or not impurities are pre...

Journal: :TELKOMNIKA (Telecommunication Computing Electronics and Control) 2017

Journal: :TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A 1997

Journal: :Experimental Mechanics 2022

Abstract Background The transverse compressive properties are integral to fully utilizing the high performing mechanical of carbon fibres (CF). Direct measurements CFs difficult. Objective A system that directly measures modulus ( E T ) by interference speckle patterns measure sub-pixel resolutions is presented. Methods compression data from an isotropic glass fibre was fitted using elastic con...

2005
A. J. W HITTLE

Calibration and Reference Blocks ................................................................. 7 Longitudinal Wave Probes ............................................................................. 7 Transverse Wave Probes ............................................................................. 10 Measurement of Steel Thickness ...........................................................

2008
N. Kirby I. Blumenfeld C. E. Clayton F. J. Decker M. J. Hogan C. Huang R. Ischebeck R. H. Iverson C. Joshi T. Katsouleas W. Lu K. A. Marsh S. Martins W. B. Mori P. Muggli E. Oz M. Zhou

In recent experiments plasma electrons became trapped in a plasma wakefield accelerator (PWFA). The transverse size of these trapped electrons on a downstream diagnostic yields an upper limit measurement of transverse normalized emittance divided by peak current, εN,x/I. The lowest upper limit for εN,x/I measured in the experiment is 1.3 ·10−10m/A.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید