نتایج جستجو برای: transformer protection scheme
تعداد نتایج: 408229 فیلتر نتایج به سال:
(Received: October 30, 2011; Accepted: December 8, 2011) Abstract: This paper presents a novel technique for transformer differential protection to prevent incorrect operation due to inrush current. The proposed method in this paper is based on time-frequency transform known as the Wavelet transform. The discrete Wavelet transform is used for analysis the differential current signals in time an...
This article presents a novel technique to distinguish between magnetizing inrush current and internal fault current of power transformer. An algorithm has been developed around the theme of the conventional differential protection method in which parallel combination of Probabilistic Neural Network (PNN) and Power Differential Protection (PDP) methods have been used. Both PNN and PDP method ar...
This paper proposes an industrial solution (equipment) for lightning and surge protection of distribution transformers. The proposed protection equipment has been installed at 100 distribution transformers (sample) of the Public Power Corporation (PPC) of Greece. The article estimates the future transformer failures, considering two different cases: (a) transformer without the proposed protecti...
This thesis describes how to provide standardized, current based, differential protection for any three-phase power transformer, including phase-shifting transformers with variable phase angle shift and transformers of all construction types and internal on-load tap-changer configurations. The use of standard transformer differential protection for such applications is considered impossible in ...
This paper presents an algorithm based on a combination of Discrete Wavelet Transforms and neural networks for detection and classification of internal faults in a twowinding three-phase transformer. Fault conditions of the transformer are simulated using ATP/EMTP in order to obtain current signals. The training process for the neural network and fault diagnosis decision are implemented using t...
For the current transformers (CTs) on the delta side measure the line current instead of the phase current, line current differential protection is adopted in transformers connected in wye-delta mode currently. However, the symmetry feature of inrush current in line current differential protection may invalidate the inrush current restrained criterion. A calculating method of current through de...
Traditionally, the protection of power transformers has been relegated to the application of transformer differential and backup overcurrent relays to provide shortcircuit protection. With the advent of modern multifunction transformer packages, differential and overcurrent protection are only two of many protective and logic functions that can be incorporated into the transformer protection pa...
Power transformers are key components for electrical energy transfer in a Power system. In order to protect the transformers from these faults different protective methods are adopted. Some of them are differential protection, over excitation Protection, etc. In this Paper Over Voltage protection is established for the protection of the transformer. Microcontroller is used for the Power Transfo...
Energizing of large power transformers is considered a critical event in the operation of an electric power system. When a transformer is energized by the grid or utility, it takes very high value current known as inrush current, the typical value of this current could be ten times. This inrush causes many problems like mechanical stress on transformer & harmonics injection to generator winding...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید