نتایج جستجو برای: tonometry
تعداد نتایج: 2118 فیلتر نتایج به سال:
INTRODUCTION Intraocular pressure (IOP) determination using dynamic contour tonometry (DCT) has been considered to be independent of central corneal thickness (CCT), while Goldmann applanation tonometry (GAT) is known to be influenced by various corneal properties. In this study, IOP was measured before and 1 day after cataract surgery using GAT and DCT to investigate the possible effects of co...
Objective: To determine the changes in corneal epithelial thickness and central using optic coherence tomography taken after Goldmann applanation tonometry measurements. Material Methods: The study included 25 patients who presented at our clinic for routine ophthalmological examination. Before taking measurements of patients, values were determined cohence (OCT). intraocular pressure (IOP) was...
A clinical evaluation of a new electron ProTon tonometer was performed comparing the values of intraocular pressure (IOP) measured using this instrument with those determined by a similar instrument, Tono-Pen XL, and by Goldmann applanation tonometry. The mean IOP measured in 106 eyes with the ProTon tonometer was not significantly different from that determined with Goldmann applanation, while...
PURPOSE To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in keratoconic corneas and to investigate the effects of central corneal thickness (CCT) and corneal radius of curvature (CR) on IOP measurements. METHODS Sixty-three eyes of 63 keratoconus patients were enrolled in t...
The effect of corneal edema and the effect of penetrating keratoplasty upon the accuracy of electronic applanation tonometry were studied in rabbits. Pressure readings made directly from cannulas in the anterior chamber correlated well with those made by electronic applanation tonometry both in severe corneal edema and 24 hours after penetrating keratoplasty. The advantages of electronic applan...
PURPOSE Rebound tonometry has recently been modified for its use in humans. The purpose of our study was to determine the precision of the ICare(R) rebound tonometer (RBT) as compared with the Goldmann applanation tonometer (GAT). METHODS Patients were recruited from our Hospital's Glaucoma Unit. In each patient, intraocular pressure (IOP) was measured without anaesthesia using the RBT and te...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید