Journal: :journal of biomedical physics and engineering 0
a r farajollahi f bouzarjomehri m kiani

normal 0 false false false en-us x-none fa introduction: in radiation therapy centers across iran, protection of normal tissues is usually accomplished by either cerrobend or lead block shielding. in this study, the influence of these two shielding methods on central axis dose distribution of photon beam a cobalt unit was investigated in clinical conditions. materials and methods: all measureme...

2007
L. Strauss

In the field of thermoluminescence dosimetry the daily analysis of multi-peak glow curves includes computerized curve-fitting methods, the so-called deconvolutions. These are in need of restricting the kinetic parameters E and s in order to obtain physically relevant results. There have been suggested various methods for the determination of these kinetic parameters based on a theory treating s...

Journal: :journal of medical signals and sensors 0
daryoush shahbazi-gahrouei saba ayat

introduction: radioiodine therapy is an effective method for treating thyroid cancer carcinoma, but it has some affects on normal tissues, hence dosimetry of vital organs are important to weigh the risks and benefits of this method. the aim of this study is to measure the absorbed doses of important organs by mcnp (monte carlo n particle) simulation and comparing the results of different method...

2012
M. I. Teixeira

In preparing of thermoluminescent dosimeters (TLD) it is common to use as agglutinator the polytetrafluoroethylene (PTFE), called Teflon. In this paper the physical, morphological and dosimetric characteristics of Teflon were evaluated aiming its application in thermoluminescent dosimetry. The differential thermal analysis (DTA) and thermogravimetry (TG) results showed that the Teflon glass tra...

2011
M. Giglioli

Since the beginning of its use, radiation has already presented harm, justifying the necessity of controlled use. In order to monitor its effects and even avoid them, dosimetry has arisen. For the purpose of ensured all the necessary safety and monitor areas where there is radiation use, a lot of devices able to identify and quantify many types of radiation were developed. However, some these d...

1999
Ramesh C. Tailor J. Francisco Aguirre William F. Hanson

The Radiological Physics Center (RPC) has been utilizing TLD to verify photon-beam output, and electron-beam output and energy for many years. The RPC currently monitors over 1200 institutions, monitoring 4000 photon and 3500 electron beams per year. Control TLD, irradiated on one specific Co-60 machine, are used for a performance check of our TLD system. Analysis of these data over 5 years, re...

2017
Li-Hong Yao Jun-Jie Wang Charles Shang Ping Jiang Lei Lin Hai-Tao Sun Lu Liu Hao Liu Di He Rui-Jie Yang

BACKGROUND A novel radioactive 125I seed-loaded biliary stent has been used for patients with malignant biliary obstruction. However, the dosimetric characteristics of the stents remain unclear. Therefore, we aimed to describe the dosimetry of the stents of different lengths - with different number as well as activities of 125I seeds. METHODS The radiation dosimetry of three representative ra...

2015
Raffaele Liuzzi Federica Savino Vittoria D’Avino Mariagabriella Pugliese Laura Cella Gabriele Multhoff

BACKGROUND Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for qua...

Journal: :Medical physics 2010
H Schiefer A Fogliata G Nicolini L Cozzi W W Seelentag E Born F Hasenbalg J Roth B Schnekenburger K Münch-Berndl V Vallet M Pachoud B Reiner G Dipasquale B Krusche M K Fix

PURPOSE In 2008, a national intensity modulated radiation therapy (IMRT) dosimetry intercomparison was carried out for all 23 radiation oncology institutions in Switzerland. It was the aim to check the treatment chain focused on the planning, dose calculation, and irradiation process. METHODS A thorax phantom with inhomogeneities was used, in which thermoluminescence dosimeter (TLD) and ioniz...