OBJECTIVE To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. METHODS One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acq...
Radiation effects of photon irradiation in Ytterbium-doped silica optical fibers are still much less explored despite their importance in space-based application as radiation dosimetry. This study investigates and compares the thermoluminescence glow curve, response, linearity and sensitivity of Ytterbium-doped SiO2 optical fibers with that of TLD-100. Samples are placed in solid phantom and ir...
PURPOSE Analyze the characteristics of TLD LiF-100 powder between multiple LiF crystal batches. METHODS The RPC used TLD LiF-100 encapsulated powder to verify the output for photon and electron beams for 4 to 23 MV X-ray beams and 6 to 23 MeV electron beams, respectively, from the past 15 years. During that time period, the RPC commissioned more than 15 batches of TLD powder. Commissioning of...
Important thermoluminescence (TL) properties of five (5) different core sizes Ge-doped optical fibers have been studied to develop new TL material with better response. These are drawn from same preform applying different speed and tension during drawing phase to produce Ge-doped optical fibers with five (5) different core sizes. The results of the investigations are also compared with most com...
BACKGROUND Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for qua...
An anthropomorphic head phantom, constructed from a water-equivalent plastic shell with only a spherical target, was modified to include a nonspherical target (pituitary) and an adjacent organ at risk (OAR) (optic chiasm), within 2 mm, simulating the anatomy encountered when treating acromegaly. The target and OAR spatial proximity provided a more realistic treatment planning and dose delivery ...
BACKGROUND Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a recently described method of post processing routine cine acquisitions which aims to provide quantitative measurements of circumferentially and radially directed ventricular wall strain. Inter-study reproducibility is important for serial assessments however has not been defined for CMR-FT. METHODS 16 healt...
PURPOSE It is known that submaximal eccentric exercise does not confer as strong a protective effect as maximal eccentric exercise. This study tested the hypothesis that four bouts of submaximal eccentric exercise would confer a similar protective effect to one bout maximal eccentric exercise. METHODS Thirty untrained men were placed into 4 x 40% (40%) or control (CON) groups (n = 15 per grou...
The Radiological Physics Center (RPC) has been utilizing TLD to verify photon-beam output, and electron-beam output and energy for many years. The RPC currently monitors over 1200 institutions, monitoring 4000 photon and 3500 electron beams per year. Control TLD, irradiated on one specific Co-60 machine, are used for a performance check of our TLD system. Analysis of these data over 5 years, re...