نتایج جستجو برای: titanium alloy ti

تعداد نتایج: 109413  

2009
J. Andrieux

Reaction zones formed at 790 °C between solid titanium and liquid Ag-Cu eutectic alloys (pure and Ti-saturated) have been characterized. When pure Ag-Cu eutectic alloy with 40 at.% Cu is used, the interface reaction layer sequence is: αTi / Ti2Cu / TiCu / Ti3Cu4 / TiCu4 / L. Because of the fast dissolution rate of Ti in the alloy, the reaction zone remains very thin (3-6 μm) whatever the reacti...

Journal: :The journal of contemporary dental practice 2007
Khalid A Al Wazzan Ibrahim S Al Hussaini

AIMS The aims of this study were to investigate the influence of commercially pure titanium (PTi) and titanium-aluminum-vanadium (Ti-6Al-4V) alloys (TiA) on the final shade of low-fusing porcelain bonded to them and to compare the shade changes with those of three conventional metal-ceramic systems. METHODS AND MATERIALS A titanium casting unit was used to cast PTi and Ti-6Al-4V alloy specime...

2003
F. Lanza G. Bertolini

Previous experiments have shown that tritium is produced in deuterated titanium. To better define the phenomenon a series of tests have been performed using various metals and alloys and different deuterating conditions. Sheets and shavings of titanium, zirconium, hafnium, tantalum, Zircaloy 2 and Ti-Zr 50% alloy have been tested. A statistical analysis of the tritium production shows that sign...

2016

This article presents the mechanical properties and microstructure of titanium alloy after selective laser melting (SLM). Titanium alloys are ideal material for selective laser melting (SLM), because they are expensive and difficult to machinery using traditional technologies. The application of SLM in the biomedical area has been slow due to the stringent performance criteria and concerns rela...

Journal: :Brazilian oral research 2012
Adriana Cláudia Lapria Faria Angelo Rafael de Vito Bordin Vinícius Pedrazzi Renata Cristina Silveira Rodrigues Ricardo Faria Ribeiro

Dental implants have increased the use of titanium and titanium alloys in prosthetic applications. Whitening toothpastes with peroxides are available for patients with high aesthetic requirements, but the effect of whitening toothpastes on titanium surfaces is not yet known, although titanium is prone to fluoride ion attack. Thus, the aim of the present study was to compare Ti-5Ta alloy to cp T...

2007
Pedro César Garcia Oliveira Gelson Luis Adabo Ricardo Faria Ribeiro Sicknan Soares da Rocha Fabiano Araújo Ávila Accácio Lins do Valle

The aim of the work was to evaluate the influence of the temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy casting. Were obtained for the tensile strength test dumbbell rods that were invested in the Rematitan Plus investment and casting in the Discovery machine cast. Thirty specimens were obtained, fifteen to the CP Titanium and fiftee...

Journal: :فصلنامه علمی پژوهشی مهندسی مکانیک جامدات واحد خمینی شهر 0
amir qysryan ma, identification and selection of materials engineering, university of kashan, kashan, iran. mahmood abasi assistant professor, faculty of engineering, department of materials and metallurgical engineering, university of kashan, kashan, iran

ti-6al-4v titanium alloy has great application in medicine and military industries due to its capabilities, namely high strength to weight ratio and corrosion resistance. in the current research, the effect of aging treatment on microstructure and wear behavior of ti-6al-4v titanium alloy was investigated. pin on disk wear test was applied to assess the wear behavior. specimens were first solut...

2009
Tadao Onzawa Akio Suzumura Jong Hoon Kim

Fiber reinforced metal composites were fabricated by diffusion welding. The matrices used were commercially pure titanium (CPTi) and two kinds of titanium alloys (Ti-6A1-4V and Ti-21V-4A1), and the filaments were two kinds of SiC-CVD fiber. The structure and the distribution of elements in reaction zone between matrix and filament both in as-fabricated state and in heat-treated state were inves...

2009
Young-Min Kim Mong-Sook Vang Hong-So Yang Sang-Won Park Hyun-Pil Lim

STATEMENT OF PROBLEM The success of titanium implants is due to osseointegration or the direct contact of the implant surface and bone without a fibrous connective tissue interface. PURPOSE The purpose of this study was to evaluate the osteoblast precursor response to titanium - 10 tantalum - 10 niobium (Ti-Ta-Nb) alloy and its sputtered coating. MATERIAL AND METHODS Ti-Ta-Nb coatings were ...

2017
Garima Bhardwaj Thomas J Webster

BACKGROUND The attachment and initial growth of bacteria on an implant surface dictates the progression of infection. Treatment often requires aggressive antibiotic use, which does not always work. To overcome the difficulties faced in systemic and local antibiotic delivery, scientists have forayed into using alternative techniques, which includes implant surface modifications that prevent init...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید