نتایج جستجو برای: thorax phantom
تعداد نتایج: 24331 فیلتر نتایج به سال:
Studying complex thorax breating motion is an important research topic for accurate fusion of functional and anatomical data, radiotherapy planning or reduction of breathing motion artifacts. We investigate segmented CT lung, airway and diaphragm surfaces at several different breathing states between Functional Residual and Total Lung Capacity. In general, it is hard to robustly derive correspo...
Attenuation correction is very important for quantitative SPECT imaging. We designed an uncollimated non-uniform line array source (non-uniform LAS) for attenuation correction based on transmission computed tomography (TCT) using Tc-99m and compared its performance with an uncollimated uniform line array source (uniform LAS) in a thorax phantom study. This non-uniform LAS was attached to one ca...
BACKGROUND To analyse limits and capabilities in dose calculation of collapsed-cone-convolution (CCC) algorithm implemented in helical tomotherapy (HT) treatment planning system for thorax lesions. METHODS The agreement between measured and calculated dose was verified both in homogeneous (Cheese Phantom) and in a custom-made inhomogeneous phantom. The inhomogeneous phantom was employed to mi...
PURPOSE To develop an anthropomorphic phantom to simulate heart, lung, and blood motion. Magnetic resonance imaging (MRI) is sensitive to image distortion and artifacts caused by motion. Imaging phantoms are used to test new sequences, but generally, these phantoms lack physiological motion. For the validation of new MR-based endovascular interventional and other techniques, we developed a dyna...
Purpose: The aim of this study was to relate lesion detectability to image contrast and noise for fi ve diff erent PET scanners, by performing an observer study of thorax phantom images. Methods: A thorax phantom containing four fi llable spheres with diameters of 10, 13, 17 and 23 mm in the mediastinal region, as well as cold lung, liver and spine inserts, was fi lled with 20 MBq F. The activi...
Background: High-resolution CT (HRCT) thorax has increase demand due to its advantage in diagnosing chronic respiratory diseases. The feasibility of matrix size with different tube voltage the HRCT protocol is unknown. Therefore, this study aimed compare effect sizes and on image quality radiation dose adult thorax. Methods: A Phantom experiment was performed, followed by...
BACKGROUND To investigate the feasibility and accuracy of dose calculation in cone beam CT (CBCT) data sets. METHODS Kilovoltage CBCT images were acquired with the Elekta XVI system, CT studies generated with a conventional multi-slice CT scanner (Siemens Somatom Sensation Open) served as reference images. Material specific volumes of interest (VOI) were defined for commercial CT Phantoms (CA...
background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...
In computed tomography, analytical fan-beam (FB) and cone-beam (CB) image reconstruction often involves a view-dependent data differentiation. The implementation of this differentiation step is critical in terms of resolution and image quality. In this work, we present a new differentiation scheme that is robust to changes in the data acquisition geometry and to coarse view sampling. Our scheme...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید