نتایج جستجو برای: strut mechanisms

تعداد نتایج: 538701  

2017
Liqun Hou Weiming Yan Shicai Chen Ruiyun Zhang Yue Qi

Due to the scarcity of rational models for predicting the strength of RC beam-column sandwich joints, a modified simplified softened strut-and-tie model suggests a more rational calculation method for the effective compressive strength and the height of the joint concrete based on the simplified softened strut-and-tie. The shear strength of existing tested 15 sandwich interior joints is calcula...

2012
Yung Chang Chen Po Yi Tsai

The roll center is one of the key parameters for designing a suspension. Several driving characteristics are affected significantly by the migration of the roll center during the suspension’s motion. The strut/SLA (strut/short-long-arm) suspension, which is widely used in production cars, combines the space-saving characteristics of a MacPherson strut suspension with some of the preferred handl...

Journal: :The Journal of invasive cardiology 2014
Yasuharu Lee Akihiro Tanaka Naoki Mori Takahiro Yoshimura Daisuke Nakamura Masayuki Taniike Nobuhiko Makino Yasuyuki Egami Ryu Shutta Jun Tanouchi Masami Nishino

AIM Percutaneous coronary intervention (PCI) for severe calcified lesions is still challenging, and there are few studies of drug-eluting stent (DES) implantation for severe calcified lesions, especially regarding long-term results and hemodialysis patients. The study purpose was to clarify the factors, including DES strut thickness, that affect the long-term outcome of severe calcified lesion ...

Journal: :The Laryngoscope 2014
Sanjeet S Grewal Almaz Kurbanov Amjad Anaizi Jeffrey T Keller Philip V Theodosopoulos Lee A Zimmer

OBJECTIVES/HYPOTHESIS The maxillary strut is the bone that separates the foramen rotundum and superior orbital fissure. Tumors involving the lateral wall of the sphenoid sinus, posterior ethmoid, or posterior maxillary sinus may invade this region. The authors detail the anatomy of the strut and present a case series that emphasizes the importance and utility of this useful landmark during an e...

Journal: :JACC. Cardiovascular interventions 2014
Jung-Sun Kim Jinyong Ha Byeong-Keuk Kim Dong-Ho Shin Young-Guk Ko Donghoon Choi Yangsoo Jang Myeong-Ki Hong

OBJECTIVES This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. BACKGROUND Tracking the fate of interested regions of struts at different time points has not been investigated. METHODS Post-intervention and 6-month follow-up optical coherence tomographic evaluations were per...

2017
Koun Yamauchi Kazunari Fushimi Kei Miyamoto Akira Hioki Katsuji Shimizu Haruhiko Akiyama

Study Design Retrospective study. Purpose The purpose of this study was to investigate the influence of sagittal alignment of the strut graft on graft subsidence and clinical outcomes after anterior cervical corpectomy and fusion (ACCF). Overview of Literature ACCF is a common technique for the treatment of various cervical pathologies. Although graft subsidence sometimes occurs after ACCF,...

Journal: :international journal of civil engineering 0
a. arabzadeh a.r. rahaie a. aghayari

in this paper a new method based on strut-and-tie model (stm) is proposed to determine the shear capacity of simply supported rc deep beams and an efficiency factor for concrete with considering the effect of web reinforcements. it is assumed that, the total carried shear force by rc deep beam provided by two independent resistance, namely diagonal concrete strut due to strut-and-tie mechanism ...

Journal: :European heart journal 2016
Tommaso Gori Thomas Jansen Melissa Weissner Nicolas Foin Philip Wenzel Eberhard Schulz Stephane Cook Thomas Münzel

BACKGROUND Peri-stent coronary evaginations may disturb flow and have been proposed as possible risk factor for late stent thrombosis. We describe incidence, predictors, and possible mechanisms of coronary evaginations 12 months after implantation of bioresorbable vascular scaffolds (BVS). METHODS AND RESULTS One hundred and two BVS implanted in 90 patients (age 63 ± 13 years, 71 males, 14 di...

Journal: :Circulation 2005
Brinda Balakrishnan Abraham R Tzafriri Philip Seifert Adam Groothuis Campbell Rogers Elazer R Edelman

BACKGROUND The intricacies of stent design, local pharmacology, tissue biology, and rheology preclude an intuitive understanding of drug distribution and deposition from drug-eluting stents (DES). METHODS AND RESULTS A coupled computational fluid dynamics and mass transfer model was applied to predict drug deposition for single and overlapping DES. Drug deposition appeared not only beneath re...

2016
Yuan Zhang Xu Deng Dianming Jiang Xiaoji Luo Ke Tang Zenghui Zhao Weiyang Zhong Tao Lei Zhengxue Quan

To assess the long-term clinical and radiographic outcomes of anterior cervical corpectomy and fusion (ACCF) with a neotype nano-hydroxyapatite/polyamide 66 (n-HA/PA66) strut in the treatment of cervical spondylotic myelopathy (CSM). Fifty patients with CSM who underwent 1- or 2-level ACCF with n-HA/PA66 struts were retrospectively investigated. With a mean follow-up of 79.6 months, the overall...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید