نتایج جستجو برای: selective electrode
تعداد نتایج: 259963 فیلتر نتایج به سال:
The preparation of polymer membrane selective to Iron(II) ion and its application to ion-selectiveelectrode is reported here. PVC membrane contains Iron–selective N-phenylaza-15-crown-5 asionophore. The membrane electrode is highly selective to Iron(II) ion and exhibit good linearresponse over a wide concentration range of 1.0 × 10-2 to 1.0 × 10-6 M with Nernstian slope of29.2 ± 0.6 mV per deca...
چکیده ندارد.
a new al(iii) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (pvc) matrix is coated on platinum wire to determine trace amounts of al(iii) ion in various samples. the sensor exhibits a good response for al(iii) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 m with nernstian slope of 19.64 ± 0.15 mv decade-1...
tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...
in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...
in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...
چکیده ندارد.
a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best performance was...
a pvc membrane fe(iii) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.the electrode exhibits a good potentiometric response for fe(iii) over a wideconcentration range 1.0×10-4 to 1.0×10-1m with a slope 19.4±0.5 mv/decade a and a working phrange of 6.5-9.0. it has a fast response time ≤30s.the best performance was observed with themembrance having the 30....
we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید