نتایج جستجو برای: reinforced concrete flat slab

تعداد نتایج: 173153  

Journal: :IOP Conference Series: Materials Science and Engineering 2019

ژورنال: مواد پرانرژی 2016

In this paper, modeling of high speed projectiles with different nose shapes, penetrating into steel fiber reinforced concrete is investigated. This is a novel study because it considers the length to diameter ratio of steel fiber as well as projectile length to diameter ratio and volume fraction of fiber used in concrete matrix on the impact resistance of steel fiber reinforced concrete fibers...

In this paper, modeling of high speed projectiles with different nose shapes, penetrating into steel fiber reinforced concrete is investigated. This is a novel study because it considers the length to diameter ratio of steel fiber as well as projectile length to diameter ratio and volume fraction of fiber used in concrete matrix on the impact resistance of steel fiber reinforced concrete fibers...

2017
B. F. ROCHA

Resumo This research investigates reinforced concrete plates and shells with skew reinforcement whose directions are not aligned with the principal internal forces. Two normal forces, one tangential force, two bending moments, and one twisting moment are defined in the plane of the element. The analysis includes two shear forces in the transverse direction. The membrane and flexural forces are ...

Journal: :E3S web of conferences 2021

In the article, authors present results of a study flat reinforced concrete beamless floor an existing building. The experiment consisted loading slab in span with water tanks. There were 15 stages total, on average 4 kN. During experiment, data was obtained relative deformations and reinforcement support. Also, observations growth vertical cracks introduced.

2012
Matthew Smith Matt E. Thomas

Synopsis: The structural design for the East Addition to the St. Cloud Hospital facility in central Minnesota incorporated punching shear and cracked section design criteria that are not currently specified in ACI 318-05. The complexity of the column layout and shallow floor-to-floor spacing were the primary reasons for choosing a twoway 12 in. (300 mm) reinforced concrete flat slab for the 450...

2016
P. Olmati

Flat slab concrete buildings are widely found in infrastructure such as office and residential buildings or industrial facilities. The susceptibility of progressive collapse of such structures due to accidental loads is highly dependent on the structural performance of the slab-column connections. This paper presents a framework for a simplified reliability analysis and derivation of safety fac...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید