نتایج جستجو برای: ramp junction

تعداد نتایج: 56999  

Journal: :Clinical biomechanics 2011
M Kongsgaard C H Nielsen S Hegnsvad P Aagaard S P Magnusson

BACKGROUND Ultrasonography has been widely applied for in vivo measurements of tendon mechanical properties. Assessments of human Achilles tendon mechanical properties have received great interest. Achilles tendon injuries predominantly occur in the tendon region between the Achilles-soleus myotendinous junction and Achilles-calcaneus osteotendinous junction i.e. in the free Achilles tendon. Ho...

Journal: :Journal of applied physiology 2007
Graydon H Raymer Sean C Forbes John M Kowalchuk R Terry Thompson Greg D Marsh

The effects of prior moderate- and prior heavy-intensity exercise on the subsequent metabolic response to incremental exercise were examined. Healthy, young adult subjects (n = 8) performed three randomized plantar-flexion exercise tests: 1) an incremental exercise test (approximately 0.6 W/min) to volitional fatigue (Ramp); 2) Ramp preceded by 6 min of moderate-intensity, constant-load exercis...

2003
Kaan Ozbay

One of the major criticisms of ramp-metering has been the delay caused on the ramps because of the queues created by ramp control strategies. However, recently, several researchers proposed strategies that explicitly take into account ramp queues when determining metering rates. In this paper, an isolated “feedback” based ramp-metering strategy using modeling is presented. In addition to the re...

2001
Mehdi Fardmanesh Juergen Schubert Rizwan Akram Ali Bozbey Marcel Bick Marko Banzet D. Lomparski Willi Zander Yi Zhang Hans-Jochen Krause

Step edge grain boundary (GB) junctions and rfSQUIDs have been made using pulsed laser deposited Y-Ba-Cu-O films on crystalline LaAlO3 substrates. The steps were developed using various ion-beam etching processes resulting in sharp and ramp type step structures. Sharp step based GB junctions showed behavior of serial junctions with resistively shunted junction (RSJ)-like characteristics. The ra...

2004
David Levinson Lei Zhang

Ramp meters in the Twin Cities have been turned off for eight weeks in fall 2000 in an experiment testing their effectiveness. This chapter analyzes the data collected during the experiment on several representative freeways during the afternoon peak period. Several performance measures for ramp metering including mobility, equity, consumers’ surplus, productivity, accessibility, and travel tim...

2006
David Levinson Lei Zhang

Ramp meters in the Twin Cities have been the subject of a recent test of their effectiveness, involving turning them off for eight weeks. This paper analyzes the results with and without ramp metering for several representative freeways during the afternoon peak period. Seven performance measures: mobility, equity, productivity, consumers’ surplus, accessibility, travel time variation and trave...

2009
Yinhai Wang Kenneth A. Perrine Yunteng Lao

Ramp metering has been broadly accepted and deployed as an effective countermeasure against both recurrent and non-recurrent congestion on freeways. However, many current ramp metering algorithms tend to improve only freeway travels using local detectors' inputs and overlook the negative impacts on local streets. This may generate two problems: 1) the optimal local settings may not result in a ...

The results of psychophysical studies suggest that displacement velocity may contribute significantly to the sensation of subcortical somatosensory neurons. The cortical correlates of these phenomena, however, are not known. In the present study the responses of rapidly adapting (RA) neurons in the forelimb region of cat primary somatosensory cortex (SI) to controlled displacement of skin and h...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید