نتایج جستجو برای: radiotherapy setup errors

تعداد نتایج: 233995  

Introduction: The aim of this study was to determine the accuracy of two different immobilization methods in patient positioning in cranial radiotherapy. The six-dimensional (6D) target localization accuracy of using a dedicated stereotactic mask was compared with that of a conventional head mask by the ExacTrac system. Material and Methods: ...

Journal: :Radiation oncology 2018
Jean-Paul J E Kleijnen Bram van Asselen Martijn Intven Johannes P M Burbach Marielle E P Philippens Jan J W Lagendijk Bas W Raaymakers

BACKGROUND Rectal cancer patients that show a pathological complete response (pCR) after neo-adjuvant chemo-radiotherapy, have better prognosis. To increase pCR rates several studies escalate the tumor irradiation dose. However, due to lacking tumor contrast on online imaging techniques, no direct tumor setup can be performed and large boost margins are needed to ensure tumor coverage. The purp...

2000
John E. McGary Walter Grant

A prostate treatment immobilization system was evaluated with respect to setup errors and efficiency for a specific treatment setup. Prostate patients were treated in the prone position with a rectal catheter using the NOMOS intensity modulated radiotherapy system. Immobilization and setup consisted of a Vac-Loktrade mark bag (MED-TEC, Orange City, IO) fitted within a registration carrier box w...

2014
Aydan SONMEZ Cem ONAL Serhat SONMEZ Gungor ARSLAN Cem PARLAK Erkan TOPKAN Melek YAVUZ

This study is aimed to evaluate the effects of setup errors on dose distribution for target volume and healthy tissue within the irradiated volume and also critical surrounding organs for breast radiotherapy (RT) using both the tangential field and the field-in-field (FIF) technique. Ten patients with breast cancer were enrolled. For each patients two plans were generated; tangential field plan...

Journal: :iranian journal of medical physics 0
hamidreza baghani ph.d. student, radiation-medicine dept., nuclear engineering faculty, shahid beheshti university, tehran, iran seyed mahmoodreza aghamiri associate professor, radiation-medicine dept., nuclear engineering faculty, shahid beheshti university, tehran, iran hossein gharaati associate professor, medical engineering and physics dept., medical faculty, medical science university of tehran, tehran, iran seyed rabie mahdavi assistant professor, medical physics dept., medical faculty, medical science university of iran, tehran, iran

introduction: orthogonal radial fields are those in which the central axes are perpendicular to each other. an example of these orthogonal fields is the set of craniospinal orthogonal fields that are used for radiotherapy of medulloblastoma. craniospinal radial fields consist of two parallel-opposed fields for brain exposure and one or two posterior spinal fields for spinal cord exposure. the m...

Journal: :Medical physics 2005
Sarah A Boswell Robert Jeraj Kenneth J Ruchala Gustavo H Olivera Hazim A Jaradat Joshua A James Alonso Gutierrez Dave Pearson Gary Frank T Rock Mackie

An accurate means of determining and correcting for daily patient setup errors is important to the cancer outcome in radiotherapy. While many tools have been developed to detect setup errors, difficulty may arise in accurately adjusting the patient to account for the rotational error components. A novel, automated method to correct for rotational patient setup errors in helical tomotherapy is p...

Ali Shabestani Monfared, Ali-Reza Shirazi Hamed Babapour Tayyeb Allahverdi Pourfallah

Introduction Superficial X-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (Up to 300 kVp). Quality of the X-ray beam that can be expressed by Half-Value Layer (HVL), are important indices for this type of treatment effective energy of photon and Homogeneity Coefficient (HC). Materials and Methods The HC of the s...

2013
Guanghua Yan Kathryn Mittauer Yin Huang Bo Lu Chihray Liu Jonathan G. Li

Treatment of the wrong body part due to incorrect setup is among the leading types of errors in radiotherapy. The purpose of this paper is to report an efficient automatic patient safety system (PSS) to prevent gross setup errors. The system consists of a pair of charge-coupled device (CCD) cameras mounted in treatment room, a single infrared reflective marker (IRRM) affixed on patient or immob...

Journal: :Medical physics 2012
M Cao N Cao H Cardenes A Fakiris C Desrosiers I Das

PURPOSE To evaluate the patient positioning accuracy and reproducibility of two commercially available immobilization systems for Stereotactic Body Radiotherapy (SBRT) treatment. METHODS Forty one patients with lung (n=21) or liver (n=20) malignancies were assigned to one of the two immobilization devices: Elekta stereotactic body frame (SBF) with built-in stereotactic coordinate system and C...

Journal: :Radiological physics and technology 2009
Akihiro Takemura Saori Shoji Sinichi Ueda Yuichi Kurata Tomoyasu Kumano Shigeyuki Takamatsu Masayuki Suzuki

Recent linear accelerators can perform cone-beam computed tomography to correct setup errors immediately before dose delivery. We calculated the dose distribution with setup errors acquired from cone-beam computed tomography to determine a more realistic and individual effect of setup errors. The differences in dose distribution were analyzed. The setup errors of three patients who were irradia...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید